4600 SERIES CONCEALED VERTICAL ROD EXIT DEVICE
INSTALLATION INSTRUCTIONS FOR ALUMINUM DOORS
I
-
ED01933
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325
-
9995 www.hagerco.com
5. INSTALL BOTTOM STRIKE (FOR LESS BOTTOM ROD [CLB] DEVICES, SKIP THIS STEP AND PROCEED TO STEP 6)
A.
The bottom strike tab is also off
-
center relative to its mounting holes. (See Figure 5
-
1) This is for adjustment
purposes.
B.
Insert the top strike so the tab is toward the stop as shown in Figure 5
-
1.
C.
Install the top strike with supplied mounting screws as shown in Figure 5
-
2.
Tab
Figure 5
-
1
Install the strike so this side
is closest to the stop.
Figure 5
-
2
Mounting Screws (#10
-
24 x
3/8”
Long, Flat Head)
6.
ADJUST RODS TO APPROXIMATE POSITION
A.
Ensure all latches are in the Door Closed Position. (See Figures 6
-
1). If the latch is in the Door Open
Position, manually push it back into the Door Closed position. (See Figure 6
-
2) Be careful to avoid sharp
corners on the door notch when moving the latch.
B.
The distance between the horizontal centerline and the center hole of the rod connectors should be
3
-
3/8”.
(See Figure 6
-
3) Adjust this distance by turning the rod connector inside the door, therefore screwing or
unscrewing the rod further on the latch. Make this adjustment for both the top and bottom rods.
Figure 6
-
1
Figure 6
-
3
Figure 6
-
2
Door Open
Position
Center Line
Door Closed
Position
3
-
3/8”
Rev 3, Rev Date: 2/13/20
Page 6 of 10