![background image](http://html1.mh-extra.com/html/hager/4600-series/4600-series_installation-instructions-manual_3206941005.webp)
4600 SERIES CONCEALED VERTICAL ROD EXIT DEVICE
INSTALLATION INSTRUCTIONS FOR ALUMINUM DOORS
I
-
ED01933
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325
-
9995 www.hagerco.com
3.
INSTALL LATCHES
A.
Insert the top latch and rod assembly into the door. Fasten the top latch to the door using the supplied
screws. (See Figure 3
-
1)
B.
Insert the bottom latch and rod assembly into the door. Fasten the bottom latch to the door using the
supplied screws. (Skip this step for Less Bottom Rod [CLB] devices.)
Figure 3
-
1
Mounting Screws
(1/4”
-
20
x
3/8”
Long,
Flat Head)
Latch and Rod Assembly
4. INSTALL TOP STRIKE
A.
Install top strike by turning it and inserting into the hole in the header. (See Figure 4
-
1 and 4
-
2)
B.
The top strike tab is slightly off
-
center relative to its mounting holes. (See Figure 4
-
3) This is for adjustment
purposes. Install the top strike so the tab is toward the stop as shown in Figure 4
-
3.
C.
Install top strike with supplied mounting screws as shown in Figure 4
-
2. Figure 4
-
4 shows installed strike.
Figure 4
-
1
Figure 4
-
3
Tab
Observe the inside edge of the mounting ears. The tab is cen-
tered on the right ear but on the edge of the left ear.
Install the strike so this
side is closest to the stop.
Figure 4
-
4
Mounting
Screws (#10
-
24 x
3/8”
Long, Flat
Head)
Figure 4
-
2
Rev 3, Rev Date: 2/13/20