background image

4600 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

 

INSTALLATION INSTRUCTIONS FOR ALUMINUM DOORS

 

 

 

 

I

-

ED01933

 

 

 

 

 

 

Hager Companies  139 Victor Street, St. Louis, MO 63104   (800) 325

-

9995   www.hagerco.com

 

3.

 

INSTALL LATCHES

 

 

A.

 

Insert the top latch and rod assembly into the door.  Fasten the top latch to the door using the supplied 

 

 

 

screws.  (See Figure 3

-

1)

 

 

B.

 

Insert the bottom latch and rod assembly into the door.  Fasten the bottom latch to the door using the 

 

 

 

supplied screws. (Skip this step for Less Bottom Rod [CLB] devices.)

 

 
 
 

Figure 3

-

1

 

Mounting Screws 

(1/4”

-

20 

3/8” 

Long, 

Flat Head)

 

Latch and Rod Assembly

 

4.  INSTALL TOP STRIKE

 

 

A.

 

Install top strike by turning it and inserting into the hole in the header.  (See Figure 4

-

1 and 4

-

2)  

 

 

B.

 

The top strike tab is slightly off

-

center relative to its mounting holes.  (See Figure 4

-

3)  This is for adjustment 

 

 

purposes.  Install the top strike so the tab is toward the stop as shown in Figure 4

-

3.  

 

 

C.

 

Install top strike with supplied mounting screws as shown in Figure 4

-

2.   Figure 4

-

4 shows installed strike.

 

 

Figure 4

-

1

 

Figure 4

-

3

 

Tab

 

Observe the inside edge of the mounting ears.  The tab is cen-
tered on the right ear but on the edge of the left ear.

 

Install the strike so this 
side is closest to the stop.

 

Figure 4

-

4

 

Mounting 
Screws (#10

-

24 x 

3/8” 

Long, Flat 
Head)

 

Figure 4

-

2

 

Rev 3, Rev Date: 2/13/20

 

Page 5 of 10

 

Summary of Contents for 4600 Series

Page 1: ...0K NARROW STILE CONCEALED VERTICAL ROD LESS BOTTOM ROD EXIT DEVICE CLB CONCEALED VERTICAL ROD EXIT DEVICE CONCEALED VERTICAL ROD EXIT DEVICE DOOR DOOR APPLICATION TOOLS REQUIRED CHASSIS MOUNTING SCREW...

Page 2: ...l doors Wood Screw 12 x 1 25 Phillips Pan Head 2 Holds Flush End Cap Bracket when surface mounting Flush End Cap Pack available as a replacement part 4600 CVR Latch Screw Pack available as a replaceme...

Page 3: ...tion on the exit device 4600 CVR Rod Connector Pack available as a replacement part 4600 CVR Top Latch Assembly available as a replacement part Contains 1 4600 CVR Top Latch Assembly The screws to mou...

Page 4: ...es For a door of standard height proceed to step E B For devices being used on doors of 10 foot height the top rod comes in two pieces Connect the two ends using the extension rod connector See Figure...

Page 5: ...d Latch and Rod Assembly 4 INSTALL TOP STRIKE A Install top strike by turning it and inserting into the hole in the header See Figure 4 1 and 4 2 B The top strike tab is slightly off center relative t...

Page 6: ...is closest to the stop Figure 5 2 Mounting Screws 10 24 x 3 8 Long Flat Head 6 ADJUST RODS TO APPROXIMATE POSITION A Ensure all latches are in the Door Closed Position See Figures 6 1 If the latch is...

Page 7: ...es on push side and 3 8 clearance holes on pull side Install flush end cap bracket and flush end cap If flush end cap is not flush with the device remove the flush end cap and loosen the mounting scre...

Page 8: ...or in the frame or move to an upright position to test latches 11 TEST OPERATION A Ensure the all latches are in the Door Closed Position See Figures 11 1 If the latch is in the Door Open Position man...

Page 9: ...losed Position check to see if the door is flush against the stop If the door is flush against the stop and the latches cannot go into the Door Closed Position try turning both strikes 180 degrees Thi...

Page 10: ...he push bar will return to the up position and the latch will actuate to lock the door C Cylinder Dogging Required hardware for cylinder dogging includes one 1 mortise cylinder lengths 1 1 8 1 1 4 or...