21
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
Figure 7.2 Remove PRIMO Passive Heat Seal Plates
4. Cut flex venting to appropriate length to run from
top of the appliance to the back side of the side dis-
charge assembly ensuring there are not any kinks.
Be sure that the flex venting is not so tight as to col
-
lapse where attached to the side discharge assembly
and restrict airflow. Refer to Section 3 and Figure 3.1
regarding length and pitch requirements.
Figure 7.4 Install Flex Venting to Appliance
WARNING! Risk of Fire! DO NOT
fold/kink/pinch/ob-
struct 6 inch flexible ducts.
Overheating of appliance and
combustible materials will occur.
NAILING TAB
ARROW UP
Figure 7.3 Side Discharge Assembly Nailing Tab Orientation
5. Secure the flex venting to the collars on both the ap
-
pliance and the bottom of the side discharge assembly
using the provided gear clamps. See Figure 7.4-7.7.
DISCHARGE ASSEMBLY
CENTERED IN FRAMING
6. Install self-tapping screw through gear clamp into col-
lar. Repeat for all collars. See Figure 7.5.
Figure 7.5 Install Screw into Collar
SCREW