24
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
8. Installation and Finishing - Open Top Dis-
charge
1. Remove the two outer passive heat seal plates. See
Figure 8.1 and Figure 8.2. Install collars over the
openings using hurricane screws provided in the kit.
WARNING! Risk of Overheating!
Both passive heat
side discharge assemblies included with kit
MUST
be
installed and operational. Overheating of appliance and
combustible materials will occur.
Install Assemblies and Flexible Duct - Open Top Discharge
Figure 8.1 PRIMO Passive Heat Open Top Discharge Configuration / Remove PRIMO Passive Heat Seal Plates
PASSIVE-HEAT-PRIMO Collar
PASSIVE-HEAT-PRIMO Collar
PASSIVE-HEAT-PRIMO
(Open Top Discharge*)
*The Front Discharge option, Side Discharge option or Open Top Chase
Discharge
may be installed. Installing more than one option is not allowed.
PASSIVE-HEAT-PRIMO
(Open Top Discharge*)
WARNING! Risk of Fire!
DO NOT remove HEAT-
OUT-PRIMO seal plates. Appliance will overheat.
Figure 8.2 Remove PRIMO Passive Heat Seal Plates
DO NOT
REMOVE
KNOCKOUTS
PASSIVE HEAT PRIMO
COLLAR LOCATION
LEFT AND RIGHT SIDES
SQUARE
VENT
PIPE GASKET
HEAT-OUT-PRIMO
SEAL PLATES
(Installation Option for PHSI-PRIMO Kit)