14
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
1. Remove the two outer passive heat seal plates. See
Figure 6.1 and 6.2. Install collars over the openings
using hurricane screws provided in the kit.
WARNING! Risk of Fire!
DO NOT remove HEAT-OUT-
PRIMO seal plates unless HEAT-OUT-PRIMO is installed.
Appliance will overheat. See HEAT-OUT-PRIMO installa
-
tion instructions.
6. Installation and Finishing - Front Discharge
Install Plenums and Flexible Duct
Figure 6.1 PRIMO Passive Heat Front Discharge Configuration / Remove PRIMO Passive Heat Seal Plates
PASSIVE-HEAT-PRIMO Collar
PASSIVE-HEAT-PRIMO Collar
PASSIVE-HEAT-PRIMO
(Front Discharge*)
*The Front Discharge option, Side Discharge option or Open Top Chase option
may be installed. Installing more than one option is not allowed.
DO NOT
REMOVE
KNOCKOUTS
PASSIVE HEAT PRIMO
COLLAR LOCATION
LEFT AND RIGHT SIDES
SQUARE
VENT
PIPE GASKET
HEAT-OUT-PRIMO
SEAL PLATES
Figure 6.2 Remove PRIMO Passive Heat Seal Plates
WARNING! Risk of Fire!
DO NOT remove HEAT-
OUT-PRIMO seal plates unless HEAT-OUT-PRIMO
is installed. Appliance and combustible materials will
overheat.