28
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
Figure 8.19 Two Hand Bends Complete
LOUVERS FACE FRONT OF APPLIANCE
Figure 8.17 Register Louvers Facing Front of Appliance
12. Both discharge assemblies must be mounted so the
louvers face the front of the appliance. For See-
Through appliances, both assemblies must face the
same direction. See Figure 8.17 and refer to Figure
4.3.
WARNING! Risk of Fire! DO NOT
install discharge
assemblies with louvers facing rear of appliance. Heated
air
MUST
flow toward front of appliance. Appliance and
combustible materials will overheat.
1 HAND BEND
2 HAND BENDS
Figure 8.18 One Hand Bend Complete
3 HAND BENDS
Figure 8.20 All Hand Bends Complete
13. Bend heat shields at the three hand bend lines as
shown in Fgures 8.18-8.20.