User Manual Version 3.1
47
CORR. C1-C2
To ensure seamlessly transition between the print areas of cartridge
C1
and
C2
, their
relatively horizontal print positions can be calibrated. This adjustment becomes necessary if
there are little stepped offsets in printed vertical lines between two cartridges.
The correction values can be adjusted in a range b24 and -24. One
step = 0.08 mm (
1
/
300
’’). Use the
PRINT CORR.PATT.
test to analyze the offset between the
print units.
Positive values will shift the print start of cartridge
C1
a step to the right
(relatively to cartridge
C2
), negative values will move it to the left (relatively to
cartridge
C2
).
-24, -23, ... 0, ..., +23, +24
Default:
0
Pos: 60.23 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü4_130308_CORR. C2-C3 @ 0\mod_1254842370770_912.doc @ 4669 @
CORR. C2-C3
The (horizontal) correction between the cartridges
C2
and
C3
can be set in the same way as
described in
CORR. C1-C2
.
Default:
0
Pos: 60.24 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1304_Adjust TOF_Fixed_Head @ 1\mod_1260517437834_912.doc @ 8253 @