No. A8a Enter the AT minimum temperature
No. A8b Enter the switch-on and switch-off times
No. A8c Enter flow set temperature
No. A9 Activation of screed heating function of the corresponding heat circuit
If
On
is selected, parameters
A9a - A9f
appear
A11: Second additional heat circuit on the control panel
A21, A31: When using an extension module
1
A41, A51: When using an extension module
2
A61: When using a heat circuit board
A
Setting options: See heat circuit 1
(A1 - A9)
10.3 Parameter B - HWT
• No. B1 HWT 1 setting on
available
Control of HWT 1
• HWT 1 setting on
Loxone
Control of HWT 1 by the Loxone controller
• Parameter No. B1 on
Not available
If No. B1 is set to
Not available
, Nos. B2 to B6 are not displayed.
Press on
Name
to name each HWT separately
No. B2 HWT 1 switch difference
Value at which the HWT is switched on below the set minimum temperature
Range: 1 - 40 °C
No. B3 Lower HWT limit temperature
If the HWT temperature drops below the preset value, HWT loading starts
within the set time (installer setting no. B90) regardless of the HWT time pro
-
gramme (customer setting no. 1).
• Range: 1 - 80 °C
No. B4 Activate the Legionella protection programme
No. B5 HWT set temperature for legionella protection
Temperatures of 70 °C or above for more than 3 minutes will kill all legionella
in the HWT.
No. B6 Leg. prot. week prog.
Green = active
Start legionella protection during HWT loading only
HARGASSNER
Mo,25.11.18 08:19
AT minimum temperature
Default: 20 °C
No. A8a Heating circuit 1 Summer
heating
20°C
HARGASSNER
Mo,25.11.18 08:19
ON
No. A8b Heating circuit 1 Summer
heating
06:00
Off
Off
ON
09:00
18:00
21:00
HARGASSNER
Mo,25.11.18 08:19
Flow-target
Default: 30 °C
No. A8c Heating circuit 1 Summer
heating
30°C
HARGASSNER
Mo,25.11.18 08:19
Off
ON
No. A9 Heat circuit 1 Screed dry out
HARGASSNER
Mo,25.11.18 08:19
not available
Pump
Mixer
No. A11 Heat circuit 2
Loxone
Mixer Floor Heating
INSERT NAME
HARGASSNER
Mo,25.11.18 08:19
not available
No. B1 HWT 1
available
Loxone
INSERT NAME
HARGASSNER
Mo,25.11.18 08:19
HWT temperature differential
Default: 6 °C
No. B2 HWT 1
6°C
HARGASSNER
Mo,25.11.18 08:19
Minimum HWT temperature
Default: 40 °C
No. B3 HWT 1
40 °C
HARGASSNER
Mo,25.11.18 08:19
No. B4 Legionella prot. HWT 1
Off
ON
HARGASSNER
Mo,25.11.18 08:19
Legionella setpoint
Default: 70 °C
No. B5 Legionella prot. HWT 1
70 °C
HARGASSNER
Mo,25.11.18 08:19
No. B6 Leg. prot. week prog.
17:00
--:--
--:--
--:--
M Tu W Th F Sa Su
a.
b.
d.
c.