III
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 [email protected]
23
6.6
Info Boiler
Info page about the current set / actual values of the boiler
• Current status of the boiler
• Water temperature in the boiler
• Exhaust fan speed in % of maximum
• Currently necessary fuel rate
• Flue gas oxygen value in % - measured on the lambda sensor
• Current temperature in the combustion chamber (flue gas temperature)
• Firebed level sensor position (Tongue)
• Ignition active / not active
6.7
Info AT
Info page about the current actual values of the accumulator
• Accumulator fill level display
Filling level: 80 % = red
Filling level: 30 % = blue
Filling level between 30 % and 80% = blue/red
• Return temperature Set / Is = Temperature of boiler return
• Button
One-time charge
Press the button to recharge the accumulator once to its set temperature
6.8
Info External heat
Info page about the current values of the external heat
• External heat operation indicator (
On
/
Off
)
• Current external heat sensor temperature
• External heat valve indicator (
On
/
Off
)
6.9
Consumption - info
Info page about the current overall consumption
• Only displayed if the pellet consumption display is activated in the installer
settings
6.10 Info Trend
Diagram of the last 24 hours
• Boiler temperature
• HWT temperature
• Power
• Accumulator filling level
The timeline can be set for activated service settings
HARGASSNER
Mo,25.11.18 08:19
Boiler: Combustion
Boiler temp. set: 60 °C
Actual: 62
Exhaust fan:
Feeding rate:
O2 - set: 12.0%
Actual:
Actual: 0%
Actual: 8%
Regulator
Ignition
F10/K50
Off
62°C
160°C
HARGASSNER
Mo,25.11.18 08:19
Filling level
AT pump
AT charge
Return mixer
Return temp. Set/Is
58%
ON
Off
Off
80°C/61°C
73°C
31°C
HARGASSNER
Mo,25.11.18 08:19
Off
0°C
Off
Ext. heat operation
External heat temperature
External heat valve
HARGASSNER
Mo,25.11.18 08:19
122.71 kg
Pellet consumption display
Pellet consumption
Total
HARGASSNER
0
20
40
60
80
100
-20h
-16h
-12h
-8h
-4h
Mo,25.11.18 08:19
Boiler
72°C
Power
100%
Filling level
59%
Outside Temp.
0°C
Summary of Contents for Classic 12