No. 7 Function and rotation check of storage room extraction motor
• Manual Forward and Backward of the motor to clear any blockages
Manual Forward also starts the suction turbine.
Only press the Backward button
briefly
(maximum 1 second).
No. 8 Filling the day hopper
Must be filled at restart
The indication limiter switches the turbine automatically off
No. 9 Function check of ignition
After a maximum of 1 minute, the coil should be hot
After 3 minutes the ignition coil switches off
No. 10 Function check on the exhaust fan
Maximum speed approx. 2600 rpm
No. 11 Function check or manual operation of HWT loading pump 1
Only possible when heat circuit control board
HC A
is connected
No. 12 Function check or manual operation of circulation pump HWT A
Only possible when heat circuit control board
HC A
is connected
No. 13 Function check or manual operation of HWT loading pump 1
Nos. 15 and 17 for HWT pumps 2 and 3 only possible when
HKM 1
and
HKM
2
are connected
No. 14 Function check or manual operation of circulation pump HWT 1
Nos. 16 and 18 for circulation pumps HWT 2 and 3 only possible when
HKM
1
and
HKM 2
are connected
Function check or manual operation of heat circuit pumps
No. 19 for heat circuit pump A (
HC A
)
Nos. 21 and 23 for heat circuit pumps 1 and 2 (
Boiler
)
Nos. 25, 27 and 29 for heat circuit pumps 3 and 4 and external heat circuit pump 2 (
HKM 1
)
Nos. 30, 32 and 34 for heat circuit pumps 5 and 6 and external heat circuit pump 3 (
HKM 2
)
Function and rotation check of heat circuit mixer
No. 20 for heat circuit mixer A (
HCA
)
Nos. 22 and 24 for heat circuit mixers 1 and 2 (
Boiler
)
Nos. 26 and 28 for heat circuit mixers 3 and 4 (
HKM 1
)
Nos. 31 and 33 for heat circuit mixers 5 and 6 (
HKM 2
)
No. 35 Function check or manual operation of district line pump or booster pump
HARGASSNER
Mo,25.11.18 08:19
F Suction
turbine
No. 7 Manual 0 mA
Storage room extraction auger
Backward
(max. 1 sec)
HARGASSNER
Mo,25.11.18 08:19
On
No.8 Manual 0.0 A
Refill pellets
Filling level: full
HARGASSNER
Mo,25.11.18 08:19
No. 9 Manual
Ignition
Ignition
HARGASSNER
Mo,25.11.18 08:19
On
No. 10 Manual 0 rpm
Induced draft fan
HARGASSNER
Mo,25.11.18 08:19
On
No. 11 Manual
HWT pump A
HARGASSNER
Mo,25.11.18 08:19
On
No. 12 Manual
HWT Pump A circulation pump
HARGASSNER
Mo,25.11.18 08:19
On
No. 13 Manual
HWT pump 1
HARGASSNER
Mo,25.11.18 08:19
On
No. 14 Manual
HWT pump 1 circulation pump
HARGASSNER
Mo,25.11.18 08:19
On
No. 21 Manual
Pump heating circuit 1
HARGASSNER
Mo,25.11.18 08:19
Open
No. 22 Manual
Mixer Heating circuit 1
Closed
HARGASSNER
Mo,25.11.18 08:19
On
No. 35 Manual
Distr. line pump / extern. heat
Summary of Contents for Classic 12