38
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 [email protected]
III
10.2 Parameter A - heat circuits
No. A1 Heating circuit
1
and
2
when using the extension module
0
5 options:
• Heat circuit not available
• Heat circuit with pump
• Heat circuit with pump and mixer motor for radiator heat circuit
• Heat circuit control by Loxone
• Heat circuit with pump and mixer motor for floor heat circuits
If No. A1 is set to
not available
, then No. A2 to No. A6 are not displayed
Press
Name
to name each heat circuit separately, (e.g. Living room).
No. A2 Steepness
Describes the relationship between flow and outside temperatures (see heating
curve)
• Range: 0.2 - 3.5
• Recommended settings:
• Floor heating:
0.3 - 1.0
• Radiator heating:
1.2 - 2.0
• Convector heating:
1.5 - 2.0
Change in small steps only and for a longer period
HARGASSNER
Mo,25.11.18 08:19
non-existent
Pump
Mixer
Loxone
Mixer Floor Heating
No. A1 Heat circuit 1
Name
HARGASSNER
Mo,25.11.18 08:19
calculated Flow-Set temperature: 30.0°C
Steepness
Default: 1.60
No. A2 Heat circuit 1
1.60
-20
10
5
0
-5
-10
-15
15
20
20
30
40
50
60
70
80
90
100
110
2,5
2,25
2,0
1,75
1,5
1,25
1,0
0,75
0,5
0,25
2,75 3 3,25 3,75
Outside temperature °C
St
ee
pn
es
s
Fl
ow
te
m
pe
ra
tu
re
°C
Summary of Contents for Classic 12