III
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 [email protected]
45
No. D6 Cleaning device
Automatic cleaning is only performed within the set time.
Irritating noise during the cleaning
.
No. D7 Summer shut down lock time/ All heat circuits
Duration of the switch-off delay for summer switch-off
If the outdoor temperature rises above 16 °C for the duration of the set time
(customer setting no. 11), the boiler switches off.
No. D8 Daylight saving time
Automatic changeover from summer to winter time
No. D9 Day clock / Week clock
Display day or weekly clock in the customer settings
• Day clock: Heat circuits and HWT on day clock
• Weekly clock: Heat circuits on weekly clock, HWT on day clock
• HC+HWT week clock: Heat circuits and HWT on week clock
.
No. D10 Number of blocks for week clock
Display in the customer settings
Range: 1 - 7
No. D11a Holiday mode
Switch off all the heat circuits together or separately.
No.D12 Outs. temp. shut down
Outdoor temperature thresholds individually or for all heat circuits together
No. D13 Outside sensor
Set whether an outside sensor is available
Set to
not available
for active, external heat circuits
No. D17 SD logging
Only visible when a DS card is inserted
Records the boiler's measurement data
No. D23 Info / Trend
Specify whether the graphical representation of records in the
Info / History
menu field should be shown.
No. D24 Modbus activated
Specify whether a Modbus is available.
Only visible when a Modbus ID card is inserted
No. D25 KNX activated
Specify whether a KNX building controller is available.
Only visible when a KNX ID card is inserted
No. D32 Contr. district line
If there is a demand from a heat circuit - parametrised on a controlled district
line - then the flow temperature of the district line is increased by the set value
HARGASSNER
Mo,25.11.18 08:19
ON
No. D6 Cleaning release
06:00
22:30
--:--
--:--
Off
ON
Off
HARGASSNER
Mo,25.11.18 08:19
Summer shut down lock time
Default: 120 min.
No. D7 all heat circuits
120 Min
HARGASSNER
Mo,25.11.18 08:19
no autom. switch
automatic switch
No. D8 Daylight saving time
HARGASSNER
Mo,25.11.18 08:19
No. D9 Day clock / Week clock
Day clock
Week clock
HC + HWT week clock
HARGASSNER
Mo,25.11.18 08:19
Number of blocks for week clock
Default: 2
Nr. D10
2
HARGASSNER
Mo,25.11.18 08:19
separated
all HC together
No. D11 Holiday mode
HARGASSNER
Mo,25.11.18 08:19
separated
all HC together
No.D12 Outs. temp. shut down
HARGASSNER
Mo,25.11.18 08:19
non-existent
Available
No. D13 Outside sensor
HARGASSNER
Mo,25.11.18 08:19
No
Yes
No. D17 SD logging
HARGASSNER
Mo,25.11.18 08:19
Do not display
Display
No. D23 Info / Trend
HARGASSNER
Mo,25.11.18 08:19
No
Yes
No. D24 Modbus activated
HARGASSNER
Mo,25.11.18 08:19
No
Yes
No. D25 KNX activated
HARGASSNER
Mo,25.11.18 08:19
Controlled district line superelevation
Default: 5 °C
No. D32 Contr. district line
5 °C
Summary of Contents for Classic 12
Page 64: ......