1

General Guide

The following guide illustrates how Wundafloor warm water underfloor heating systems can be coupled together 
with the majority of central heating plumbing and control systems.

The majority of modern central heating systems make use of motorised valves, often called Zone valves, to divide 
different heating systems and hot water generation ie. Radiators, Under Floor Heating and Hot water cylinder.

Systems using combination boilers will also need zone valves if separate systems of heating require different times 
and temperatures.

Quite often ground and first floors are controlled separately as they may have different uses. The zone valve acts 
like a relay, meaning any system can call the boiler/ heat source without other areas being activated.

If the underfloor system is being encorporated alongside a radiator system it is even more important that these 
areas are controlled independently as ‘heat up’ and ‘cooling off’  times are different.  We recommend the ‘S’ plan 
layout is adopted as this allows for more variety in zoning, and should be very familiar to qualified plumber/
electricians. The schematics show typical S-plan heating systems with under floor heating encorporated.

NOTE:

An Auto By-Pass valve (ABV) should be incorporated in all systems.

NOTE:

If a Heat pump manifold has been supplied then there will be no pump on the manifold. Therefore the relay on 
the H-Box wiring centre is used to switch on a shunt pump which will send primary water from a
buffer tank or the heatpump itself to the manifolds.

Wundafloor does not supply:

•  ‘S’ plan wiring centre
•  Cylinder thermostat
•  Hot water time clock
• Auto bypass valve

Motorised / Zone valves and Pipe stats are available if requested.

Plumbing and Wiring Schematics

Section A

System Boiler with hot water cylinder, radiators & UFH
1a)

 Plumbing Schematic

2a)

 Multi Zone Wiring Schematic

3a)

 Single Zone Wiring Schematic

Section B

Combination Boiler with radiators & UFH

1b) Plumbing Schematic
2b) Multi Zone Wiring Schematic
3b) Single Zone Wiring Schematic

Section C

Adding Single Zone kit to exisiting radiator system

1c) Plumbing Schematic
2c) Wiring Schematic
3c) Plumbing Schematic (Danfoss kit)

Section D

H-Box-12 Wiring Schematics

1d) H-Box-12  V1.2
2d) H-Box-12 (previous model)

Section E

Installing a Wet Room Thermostat

Section F

Schematic - Wireless Control Centre E8.583RF

Section G

Schematic - Wireless Receiver (single zone) E8.413RF / E8.423RF

E09

Installation guide - wiring & plumbing

✆ 

0800 5420 816

       

www.wundafloorheating.co.uk

THE BRAND YOU CAN TRUST

Summary of Contents for E09

Page 1: ...stems with under floor heating encorporated NOTE An Auto By Pass valve ABV should be incorporated in all systems NOTE If a Heat pump manifold has been supplied then there will be no pump on the manifold Therefore the relay on the H Box wiring centre is used to switch on a shunt pump which will send primary water from a buffer tank or the heatpump itself to the manifolds Wundafloor does not supply ...

Page 2: ...p HWC Boiler ABV Under Floor Heating system supplied by Wunda Section A 1A Schematic System Boiler with hot water cylinder radiators UFH E09 Installation guide wiring plumbing 0800 5420 816 www wundafloorheating co uk THE BRAND YOU CAN TRUST ...

Page 3: ...p E L N N L HT on HWS on Time Clock 00 00 Hot water Cylinder Stat 1 C Radiators Zone Valve M G UFH Zone Valve O B Circulating Pump Omitted for clarity Switch Relay Pump Relay L N SL B Hot Water Zone Valve 230v Input Wundafloor Programmable Thermostat Thermostat may be powered from a seperated localised fused spur Standard dial thermostats may be power from a time clock 2A Typical wiring scheme for...

Page 4: ...8 9 10 Boiler Room Stat L N L1 M B O G M O G multiple Programmable thermostats on UFH system Underfloor Heating pump E L N N L HT on HWS on Time Clock 00 00 Cylinder Stat 1 C Radiators Zone Valve M G UFH Zone Valve O B Circulating Pump Omitted for clarity Switch Relay Pump Relay L N SL B Hot Water Zone Valve 230v Input Wundafloor Programmable Thermostat Thermostat may be powered from a seperated l...

Page 5: ...E09 Installation guide wiring plumbing 0800 5420 816 www wundafloorheating co uk THE BRAND YOU CAN TRUST ...

Page 6: ...ard dial thermostats may be power from a time clock Wundafloor Programmable Thermostat S Plan Wiring centre S Plan Wiring centre 2B Typical wiring scheme for multi zone UFH with a combination boiler 3B Typical wiring scheme for single zone UFH with a combination boiler Thisdrawingisforguidanceonly All installationsshouldbeundertakenbya qualifiedpersononly Thisdrawingisforguidanceonly All installat...

Page 7: ...t may be powered from a seperated localised fused spur Standard dial thermostats may be power from a time clock Wundafloor Programmable Thermostat S Plan Wiring centre S Plan Wiring centre 3B Typical wiring scheme for single zone UFH with a combination boiler Thisdrawingisforguidanceonly All installationsshouldbeundertakenbya qualifiedpersononly Thisdrawingisforguidanceonly All installationsshould...

Page 8: ...ng system supplied by Wunda Connections to existing radiator flow return Section C 1C Schematic Adding single area UFH to an existing radiator system HWC E09 Installation guide wiring plumbing 0800 5420 816 www wundafloorheating co uk THE BRAND YOU CAN TRUST ...

Page 9: ...r from a time clock 2C wiring schematic for single zone kit added to radiator system Terminal Block Section C 2C Wiring schematic for single zone kit added to radiator system This is when a single zone underfloor heating kit is connected to an existing radiator system without an individual zone valve for the UFH and therefore unable to call the boiler heat source independently for heat Although a ...

Page 10: ...pipe The valve must be positioned on the return from the heated floor It is recommended that isolation valves are used for filling and maintenance The supply pipework must not be less than 15mm The heating engineer must check that the is adquate flow available from the heating mains Section C 3C Schematic Danfoss FHV R Kit to an existing radiator system E09 Installation guide wiring plumbing 0800 ...

Page 11: ... stat E91 713 Touch screen room stat 1 2 3 Sensor 6 7 RTC84 13 1 2 4 Wiring centre H Box 12 L N L1 L1 N Transformer Ground FUSE max 10A 2 x 5mm FAST BLOW L N L Manifold pump Max 4 actuators can be linked to one room stat Timer RTS 80 70 LIVE 1 N 2 SL 4 L N L N Optional Link V1 2 L E D Identifiable by model No ZDA0003 V1 2 on PCB and addition of L E D Dimension mm 310 W x 110 H x 55 D Ambient tempe...

Page 12: ... Sensor 6 7 1 2 4 Sensor 6 7 RTC75 713T Button room stat E91 713 Touch screen room stat 1 2 3 Sensor 6 7 RTC84 13 1 2 4 Wiring centre H Box 12 Technical Data Supply voltage 230V AC 50 60Hz Output voltage 230V AC 50 60Hz Max Load 4A Number of zone outputs 12 zones Left Hand 1 x potential free relay output Right Hand 1 x independent relay output L N L1 L1 N Transformer Ground FUSE max 10A 2 x 5mm FA...

Page 13: ...the unit s terminal block to go through prepared hole through wall and exit into supplied probe housing fixed onto interior wall of wet room at 1500 mm from wet room floor level Bathroom Stat Unit can be used as a floor temperature sensor or an air temperature sensor Bathroom stat on outside of wet room wall Ensure hole is sealed between wall space and probe housing so that only the wet room air t...

Page 14: ... Protective Housing Ip40 Weight 1 KG E8 413RF E8 423RF Wireless Receiver Single Zone Technical Data Voltage AC230V Current Max 3A Wireless Frequency Output 433Mhz Effective Transmission Distance 200m empty space Ambient Temperature 5 50 C Pump Linkage 230V sub output Boiler Zone Valve Linkage Volt free or 230V with link Protective Housing Ip40 Weight 1 KG Voltage Free Switch With Optional Link fit...

Page 15: ...7 6 5 4 3 2 1 Sensor External Probe Sensor External Probe Potential free output 3A Main Control circuit L1 N1 3A 3A N L N L L1 E8 413RF E8 423RF 15 Technical Data Voltage AC230V Current Max 3A Wireless Frequency Output 433Mhz Effective Transmission Distance 200m empty space External Limitation Value 300 C 400 C and 500 C if external probe is fitted Factory setting 300 C Limitation Switch Different...

Page 16: ...16 Your Notes Tech support opening hours are subject to change please visit our website for the latest information ...

Reviews: