4 - Sprayer Setup
65
Angling of Air and Spray Liquid - Rules of Thumb
To control wind drift, the influence of wind speed and wind direction, as well as the horizontal air current around the boom
due to forward speed must be minimized. Because it is a sum of two forces with variable direction and size that we have to
counteract for, the following can only be very rough guidelines.
Angling of Air System
The air system can be angled to counteract for the wind direction and
high driving speeds.
Angling the air system forwards: Up to 40°.
Angling the air system backwards: Up to 30°.
No angling (neutral setting): 0° = the spray nozzles points vertically
towards the ground.
The angle between the spray nozzles (A) and air channel (B) is fixed.
Wind Direction
•
Head wind: Angle the air stream forward.
•
Tail wind: Angle the air stream backwards (if the forward speed is
higher than the wind speed: angle forward).
•
Side wind/no wind: Angle the air stream vertically or backwards.
Only high driving speeds may require forward angling.
Angling forwards
Angling neutral
Angling backwards
Summary of Contents for COMMANDER 5500
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents 8 ...
Page 12: ...1 Welcome 10 ...
Page 48: ...3 Description 46 ...
Page 96: ...5 Operation 94 ...
Page 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10 ...
Page 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10 ...
Page 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections ...
Page 142: ...6 Maintenance 140 ...
Page 162: ...8 Technical Specifications 160 ...
Page 168: ...Index 166 ...
Page 169: ......