6 - Maintenance
111
1000 Hours Service - Hydraulic Oil for TWIN system, Oil Change
Next oil change is after 1000 hours or once a year, whichever comes first.
The oil change should be carried out when the machine has been running for at least one hour so that the oil is at working
temperature.
The oil tank (A) is installed near the platform.
How To Find The Filling Point
1.
Stand on the platform.
2.
Pull the plastic hose (B) out of the clamps and place it on the
platform.
3.
Unscrew the thumb screws (C).
4.
Lift away the vertical plate (D) and place it temporarily up against
the handrail to the right.
Filler neck and filling cap (E) for the oil tank is placed next to the
clean water tank.