6 - Maintenance
118
Feed Pipe Clamp Assembly
A feed pipe can be removed from the pipe clamps the following way:
1.
Use a flat bladed screwdriver to pry the cover off the first corner (A).
2.
Hold the clamp top with your hand and pry off the opposite corner
(B) with the screwdriver.
3.
Pry off the other side of the pipe clamp with the screwdriver.
4.
Take out the feed pipe.
Feed Pipe Snap-Lock Assembly
Disassembly
1.
Unscrew the union nut (A) completely.
2.
Pull the feed piping and hose barb apart.
3.
Take out the O-ring (B).
4.
Inspect and oil O-ring (B). Change the O-ring (B) if worn, before
reassembly.
Reassembly
1.
Check that the barbed lock ring (C) is fitted to the feed pipe with
barb pointing away from pipe opening.
2.
Fit the oiled O-ring (B) onto the feed pipe next to the lock ring (C).
3.
Push the feed pipe and hose barb together.
4.
Screw the union nut (A) on the hose barb and tighten union nut
(A) by hand.
Initial Assembly of Fittings
ATTENTION! This method can only be used for pipes not fitted
into pipe clamps.
1.
Fit the barbed lock ring (C) to the feed pipe with barb pointing
away from pipe opening.
2.
Fit the oiled O-ring (B) onto the feed pipe next to the lock ring (C).
3.
Screw the union nut (A) on the hose barb.
4.
Press the feed pipe and hose barb together.
5.
Tighten the union nut (A) by hand if needed.
Summary of Contents for COMMANDER 5500
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents 8 ...
Page 12: ...1 Welcome 10 ...
Page 48: ...3 Description 46 ...
Page 96: ...5 Operation 94 ...
Page 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10 ...
Page 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10 ...
Page 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections ...
Page 142: ...6 Maintenance 140 ...
Page 162: ...8 Technical Specifications 160 ...
Page 168: ...Index 166 ...
Page 169: ......