6 - Maintenance
120
With the locking piece (B) removed, place the screw driver as shown and
pull to remove the upper part (C) of the nozzle holder.
Locking piece (B) and upper part separated (C).
Inside the lower part (D), the O-ring (E) is located, and it can now be
removed for maintenance.
Note that the O-ring, when seated, is supposed to be a little out of shape
to fit tightly around the hole in the nozzle pipe.
How To Reassemble Nozzle Holder
1.
Place the O-ring inside the lower part.
2.
Place the lower part on the nozzle pipe. The O-ring fits around the
hole in the nozzle pipe, where the spray liquid exits to the nozzle
holder.
3.
Place the upper part on the opposite side of the nozzle pipe.
4.
Click the parts together by pressing relatively hard.
Summary of Contents for COMMANDER 5500
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents 8 ...
Page 12: ...1 Welcome 10 ...
Page 48: ...3 Description 46 ...
Page 96: ...5 Operation 94 ...
Page 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10 ...
Page 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10 ...
Page 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections ...