DPO6000, MPO6000 Series Digital Fluorescent Oscilloscope Product Manual V1.3
111
Selectable analog
bandwidth
limit,
typically
20MHz
Low
frequency
response (-3db)
≤10Hz at BNC
Rise time at BNC,
typical
DSO6084
DSO6104
DSO6204
≤4.4ns
<
3.5ns
≤1.8ns
Vertical gain accu-
racy
In the "normal" or "average" acquisition mode, the accuracy from 10V/div
to 10mV/div is ± 3%.
In "normal" or "average" acquisition mode, the accuracy from 5mV/div to
500uV/div is ± 4%.
DC offset accura-
cy
± 0.1div ± 2 mV ± 1% offset value
Channel Isolation DC to Maximum Bandwidth:> 40 dB
Note: The bandwidth is reduced to 6MHz when using the X1 probe
Vertical (digital channel: for MPO6000D / MPO600EDU or DPO6000B / DPO6000C
purchase digital probe LP104)
Threshold
Adjustable threshold for 4 channels as a group
Threshold selec-
tion
TTL
(
1.4 V
)
5.0 V CMOS
(
+2.5 V
)
3.3 V CMOS
(
+1.65 V
)
2.5 V CMOS
(
+1.25 V
)
1.8 V CMOS
(
+0.9 V
)
ECL
(
-
1.3 V
)
PECL
(
+3.7 V
)
LVDS
(
+1.2 V
)
0V
Custom
Threshold range
±7.0V
,
10Mv steps
Threshold accura-
cy
± (Threshold setting of 100mV + 3%)