35 / 41
Hakki Pilke 35 Falcon
Translation
Version 10
4.13. Solenoid and pressure regulating valves
The pressure regulating valves are adjusted to the correct settings at the factory. The firewood processor's
guarantee is void if the factory settings are changed. If you need to change the settings for any reason, first
contact the manufacturer or retailer and follow their instructions carefully. Changing the cartridge settings in-
correctly may damage the machine or render it hazardous to operate. If the relief valve settings need to be
changed, do it as follows: loosen the locking nut and tighten or loosen the hex socket screw as needed (when
the screw is tightened, the pressure increases and vice versa). Finally, tighten the locking nut. The locations of
the relief valves are indicated in the following figures.
1.
Relief valve of the saw motor (200 bars) Figure 43
2.
Relief valve of the splitting valve (240 bars) Figure 44
3.
Relief valve of the acceleration valve (160 bars) Figure 45
4.
Relief valve of the out-feed conveyor (200 bars) Figure 46
5.
Relief valve of the safety valve (250 bars) Figure 47