13 / 41
Hakki Pilke 35 Falcon
Translation
Version 10
Electrically powered model
An electrically powered machine func-
tions with a power of 7.5 kW. The IP rat-
ing of the electric motor is 55. The fuse
must be a min. 16 A
type D fuse
. The
electrical cable must be at least 5 x 4
mm², and it is connected to the socket in
the electric motor (Figure 6).
The firewood processor can be activated
with the green starter button on the
front section of the machine. Use the red
button to turn off the machine.
If the electric motor rotates in the wrong
direction (i.e. the machine makes an ab-
normal noise and the hydraulic functions
are inoperable), the current phase is in-
correct.
We recommend using an extension cord
that allows you to switch the current
phase, or an adapter.
Note! If the extension cord does not
have a phase switch, the electrical work
related to changing the phase must only
be performed by an electrician.
Note! Only connect the machine to a
fault current protected socket.
Figure 6