MTU
1496
(Maximum Transmission Unit) Specifies
the maximum allowed size of IP packets for
the outgoing RTP data stream.
228..1500
TTL
16
(Time-to Live for stream packets) Specifies
the number of router hops the Stream
packet is allowed to travel/pass before it
must be discarded.
1..255
ToS
184 or 0xB8
(Type of Service) Specifies the desired
quality of service (QoS). This value will be
assigned to the Type of Service field of the
IP Header for the outgoing streams.
Range = 0..255 (decimal) or 0x00..0xFF
(hex)
Default = 0xB8
NOTE:
A DiffServ or DSCP (Differentiated
Services Code Point) value must be
converted to a ToS precedence value. For
example, AF41 or DSCP 34 becomes ToS
136. For more information, see RFC2474.
Still Image
None
(Optional) Select a pre-configured static
image file to display when the stream is
paused. (See
This feature may be used for applications
such as blocking out sensitive content or
delivering announcements.
NOTE:
To configure the static images, see
VF Encryption
Off
(Read-only/Only shows if enabled)
Indicates whether Advanced Encryption
Standard (AES) encryption has been
enabled through the Furnace Server
interface (VF Station Editor).
FEC
None
(Optional) Enable Forward Error Correction
(FEC). Select either:
• (None)
• VF
NOTE:
The VF FEC is a proprietary FEC
and is not interoperable with devices
outside of the Haivision family.
Average Bandwidth
n/a
(Read-only) The average transmit
bandwidth for the unit in kbps.