GETTING STARTED
31
18
EXT A MON OUT
Output current monitor pin
Outputs approx. 0V to 10V to represent
the outuput current from 0A to
3A(400H) or 6A(800H).
19
COM
COM
Connected with the negative output
terminal.
20
EXT ALARM IN
Trigger the alarm state when short-
circuited with the COM pin.
21
EXT OUTPUT IN
Turns on the output when short-
circuited with the COM pin.
22
COM
COM
Connected with the negative output
terminal.
23
EXT CV STATUS
OUT
Open collector output. Set to the low
level when the channel is in CV mode.
24
EXT CC STATUS
OUT
Open collector output. Set to the low
level when the channel is in CC mode.
25
ALARM OUT
Open collector output. Set to the low
level when the channel is in the alarm
mode.
26
STATUS COM
COM for pins 23, 24 and 25.
All manuals and user guides at all-guides.com