PSB-2000 Series User Manual
54
activating the preset function.
OVP/OCP function
Menu Item: 02 (All Models)
Introduction
OVP: (Over Voltage Protection)
The OVP function turns off the output when the
output voltage of the PSB-2000 series exceeds
the preset OVP value.
Model
Setting Range
Resolution
PSB-2400L
PSB-2800L
PSB-2400L2
PSB-2800LS
1.0V to 84.0V
0.1V
PSB-2400H
PSB-2800H
10.0V to 840.0V
1V
OCP: (Over Current Protection)
The OCP function turns off the output when the
output current of the PSB-2000 series exceeds
the preset OCP value.
Model
Setting Range
Resolution*
PSB-2400L
PSB-2400L2
1.0A to 42.0A
0.1A
PSB-2800L
1.0A to 84.0A
0.1A
PSB-2400H
0.1A to 3.15A
0.01A
PSB-2800H
0.1A to 6.30A
0.01A
*The resolution may be different for
parallel/serial operation. Please see the
specifications for details.