PSB-2000 Series User Manual
150
Specifications
Output
Model
PSB-2400L
PSB-2800L
PSB-2400L2
PSB-2800LS
Rated output voltage
80.00V
80.00V
80.00V×2CH
80.00V
Setting accuracy
0.1% setting ±2 digit (23ºC ±5ºC)
Resolution
10mV
Display accuracy
0.2% reading ±2 digit (23ºC ±5ºC)
Rated output current
1
40.00A
80.00A
40.00A×2CH
80.00A
Setting accuracy
0.2% setting ±2 digit (23ºC ±5ºC)
Resolution
10mA
Display accuracy
0.3% reading ±2 digit (23ºC ±5ºC)
Rated output power
2
400W
800W
400W×2CH
800W
Setting accuracy
±10W
Resolution
10W
Display accuracy
0.5% reading ±5 digit (23ºC ±5ºC)
1
The maximum output current through the front output terminals is 40A.
2
Switching from the constant-voltage (CV) or constant-current (CC) mode into the
constant-power (CP) mode or vice versa is subject to over-shoot ringing, etc.
Model
PSB-2400H
PSB-2800H
Rated output voltage
800.0V
Setting accuracy
0.1% setting ±2 digit (23ºC ±5ºC)
Resolution
100mV
Display accuracy
0.2% reading ±2 digit (23ºC ±5ºC)
Rated output current
1
3.00A
6.00A
Setting accuracy
0.2% setting ±2 digit (23ºC ±5ºC)
Resolution
10mA
Display accuracy
0.3% reading ±2 digit (23ºC ±5ºC)
Rated output power
2
400W
800W
Setting accuracy
±10W
Output voltage should be at least 1% of the rated voltage
Resolution
10W
Display accuracy
0.5% reading ±5digit (23ºC ±5ºC)
1
The maximum output current through the front output terminals is 3A(2400H) or
6A(2800H).
2
Switching from the constant-voltage (CV) or constant-current (CC) mode into the
constant-power (CP) mode or vice versa is subject to over-shoot ringing, etc.
All manuals and user guides at all-guides.com