7.1.9.2 Replacing the filter cartridge on a C400
•
Press the filter cleaning push button and turn off the air supply.
ENSURE THE FILTER IS CORRECTLY POSITIONED SO THAT DUST
CANNOT BYPASS IT TO THE EXHAUST
Replace with new filter
cartridge
(Y1CA0049
standard filter,
Y1CA0045 PTFE filter)
Turn lifter cam 180° to the
right to lock cartridge
Replace front cover
For filter removal turn lifter
cam 180° to the left
The cam is now unlocked
and the filter cartridge can
be removed
Turn anti-clockwise to
unlock
Remove front cover