7.1.1 Exhaust box
7.1.2 Viewing and illumination window
Check there is enough light entering the
cabinet to work by. If not the illumination
window
(P2GL0012)
may be scratched.
Replace if necessary.
The rubber gasket
(R5SL0000)
and the
gasket filler strip
(R5SL0002)
should
also be inspected and replaced if
necessary.
Check that the view of the component to
be blasted is not impaired by a scratched
anti frost sheet
(P2PF0013)
or glass
(P2GL0009)
or a damaged wire gauze
(E1AA2681)
. Replace if necessary.
The window gasket should also be
inspected and replaced when worn
(R5SL0028)
.
Check that the base of the exhaust box
(E1AA3077)
situated in the cabinet
hopper has not worn through. If it has the
exhaust gases will fire straight at the
hopper elbow and wear it out.