![Guyson Euroblast PF Operating & Maintenance Instructions Download Page 34](http://html1.mh-extra.com/html/guyson/euroblast-pf/euroblast-pf_operating-and-maintenance-instructions_2279332034.webp)
Operation &
Maintenance
Manual
Issue: 09
A6ML0165 - Euroblast PF Manual
Date: 05/2019
Page: 34
7.1.7 Empty waste bin
The dust collector bins should be emptied twice daily. They should also be checked for good media. If
this is present then the dust collector/cyclone settings will need adjusting.
CARE SHOULD BE TAKEN WHEN HANDLING THE WASTE BINS AS THEY
MAY BE HEAVY
41 Dust collector
This bin is held in by clips on both sides of the dust
collector. Release these to remove the bin from the
dust collector.
C400 Dust collector
This bin is compressed against the filter chamber of
the dust collector by a lifter cam. To lower the bin,
use the handle on the side. Then slide the bin out.
C600 and C800 Dust collector
This bin is compressed against the filter chamber of
the dust collector by a lifter cam. To lower the bin;
use the lever on the side. Then slide the bin out.
It is essential that a plastic bin liner (Y1CA0047)
is used.
If a bin liner is not used then dust will be drawn up
into the clean side of the dust collector.
HE Cyclone waste bin
This bin is compressed against the filter chamber of
the dust collector by a lifter cam. To lower the bin;
use the lever on the side. Then slide the bin out.
The bin is also raised so a suitable lifting
mechanism can be used to move the bin.