The C600 motor can be viewed through the
mesh screening on the top of the unit.
On a C800 dust collector the motor is inside.
There is a viewing hatch on top of the dust
collector that can be opened to see the top of
the motor.
•
Start the cyclone:
o
The direction of the impellor motor should be checked visually against the arrow on
the motor. If rotation is in the wrong direction, then on a 3 phase motor two of the
input phase lines should be changed over. Guyson International should be contacted
for more information if it is a single phase motor.
NOTE:
Air will flow from the outlet even if the fan rotation is wrong, but only at a low
level, so rotation must be checked visually.
The best way to do this task is by starting then stopping the cyclone and watch the
fan as it slows down.
On a 75/16 and CY600 cyclone the motors are on
the outside and can be easily checked.
•
Turn on the air supply by opening the main air valve