Questions for pressure-feed machines
Fault
No media emitted from blast nozzle when in
cycle
Action
Possible cause
Nozzle blocked
Unblock and clean
No main line air supply
Ensure main line air valve is open
Media control valve closed
Ensure media control valve is
open to pre-set position
Ball valve in blast air line closed
Ensure valve is open
Fault
Moisture coming from blast nozzle
Action
Possible cause
Fault with customer air supply
Customer to check and correct
Fault
Air pressure from blast nozzle drops
Action
Possible cause
Compressor fault/not to specification
Customer to check and correct
Incorrect mains supply pipe diameter
Refer to Data sheets, change pipe
Worn blast nozzle
Replace
Fault
Erratic media flow from gun nozzle
Action
Possible cause
Media control valve incorrectly set.
Reset to produce even flow
Incorrect air-pressure setting
Refer to Set-up information
Questions for machines with Cyclones / Dust collectors / Sieves
Fault
Incorrect media separation
Action
Possible cause
Breather filters blocked
Replace
Hole/blockage in sieve membrane
Replace membrane
Hole in bellows/gaiter on sieve
Replace
Fault
Poor visibility/dust emissions
Action
Possible cause
Lack of negative pressure in extraction system Check machine extraction system
Poor media quality
Replace all media
If problems are ongoing please conduct a full maintenance service of the equipment
or contact Customer Services to book a Guyson Service Engineer visit