Sy
nch
ro
no
us g
en
er
at
or
s o
f s
er
ie
s D
G
G
, D
W
G a
nd W
G
Issue 05/2013
Page 56
Installation of generator
Installation of dual-bearing generators (BG 132)
Important
y
Loose belts can spring off and
do not reliably transmit the drive
power.
►
The drive belt must not sag
loosely.
When using narrow belt pulleys of type SPA, the
clearance between the axes must not exceed
600 mm. For permissible axis clearances for other
belts, ask the manufacturer.
Maximum tension force (tension) of drive belt
on the shaft
y
F
max
= 2,000 N for standard bearing plate (shaft
ø 28 mm)
y
F
max
= 3,000 N for reinforced bearing plate
(shaft ø 32 mm)
The maximum tension force indicated is
applicable for a max. clearance of 50 mm from
the point where the shaft exits the bearing
plate. If the belt pulley attachment to the shaft is
placed further out, reduce the tension of the belt
accordingly in order to balance out the increased
leverage effect on the shaft.
Quantity and type of the belts used
Adapt the quantity and type of the belts used to
the output of the generator.
Observe the maximum belt tensioning force.
F
max
l
max
Summary of Contents for BG 132
Page 118: ...page 118...
Page 119: ...page 119...
Page 120: ...page 120...
Page 121: ...page 121...
Page 123: ...Page 123 Issue 05 2013...
Page 126: ...Synchronous generators of series DGG DWG and WG Issue 05 2013 Page 126...
Page 127: ...Page 127 Issue 05 2013...