English
51
② Customize
:
Select this mode and a region box will appear on the small window. Click
the red small box next to the digital ID of the region box to drag or stretch the region.
Rule Number
:
Only one rule is allowed to be turned on. The entire screen has been checked
in the default area. If you need to customize the area, check the box in the upper left corner
of the screen, and drag the points placed at the four corners of the screen to re-divide the
detection area.
Rule Switch
:
The switch of the rule.
8.7.1.9 QD – Queue Length Detection
When the queue or the waiting time is too long, an alarm will be triggered by Queuing Detection
(QD) function.
Figure 8.25
Enable
:
Enable or disable QD
Sensitive
:
The sensitivity of Queue Length Detection can be set as 1-4. The larger the value
is, the more sensitive QD alarm is. The default sensitivity of QD is set as 2
Dynamic Marking:
choose to show or don’t show the track
Min Pixel
:
The lowest pixel setting of humans. When the recognized object is smaller than
the pixel, no alarm is generated accordingly. It can be set to 32-1080. Note: the figure
recognition function recognizes the whole picture as a 1080p picture.
Max Pixel
:
The highest pixel setting for people. When the recognized object is larger than the
pixel, no alarm will be generated accordingly. It can be set to 32-1080. Note: The image
Summary of Contents for GU-CI Series