Troubleshooting
59 | 80
BA_TD
3-
BM
000e
n_
06
4_sof
tli
Q
-M
C
.docx
Display shows
Explanation
Remedy
System overloaded!
Capacity already used up prior
to the end of the
regeneration!!
One exchanger is being
regenerated while the
other is already
exhausted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Only displayed if detection is
activated. Reduce water withdrawal,
if possible. Malfunction
acknowledges itself automatically
after regeneration has been
completed.
Malfunction control valve
regeneration!
Observe operation manual!
Step monitoring of
regeneration motor or
connecting cable
defective.
Water loss to the drain in
operating position.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Notify Grünbeck's technical service/
authorised service company.
Regeneration water meter
volume not reached!
Observe operation manual!
Regeneration water meter
is not emitting any pulses.
Connecting cable
defective.
Water supply interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check soft water meter!
Observe operation manual!
Soft water meter is not
emitting pulses.
Connecting cable
defective.
Water supply interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check regeneration water
meter!
Observe operation manual
Regeneration water meter
is not emitting any pulses.
Connecting cable
defective.
Water supply interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check blending water
meter!
Observe operation manual
Blending water meter is
not emitting any pulses.
Connecting cable
defective.
Water supply interrupted.
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
System is not drawing brine
from the brine tank
effectively!
Observe operation manual!
Minimum contact during
salting not reached.
Monitoring time
exceeded.
Injector clogged or raw
water pressure too low.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Notify Grünbeck's technical service/
authorised service company.