Model G0854 (Mfd. Since 08/18)
-31-
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
The test run consists of verifying the following:
• Glue pot powers up and reaches temperature
of 180° C (356° F)
• Each motor powers up and runs correctly
• Emergency Stop button works correctly
• Safety limit switches work correctly
To test run machine:
1. Read and follow safety instructions at begin-
ning of manual, take all required safety pre-
cautions, and make sure all previous setup/
assembly steps in this manual have been
followed and completed.
2. Ensure panel feeder is closed and locked,
and rear access door is closed. If either of
these items is not properly closed, machine
will not function.
3. Clear all setup tools and loose items away
from machine.
4. Make sure master power switch is turned
OFF and Emergency Stop button is pressed
in.
5. Connect machine to power by inserting power
cord plug into a matching receptacle, then
connect machine to an air supply and adjust
air regulator to 100 PSI.
6. Twist Emergency Stop button clockwise until
it springs out (see
Figure 37). This resets
switch so machine can start.
7. Turn
master
power
switch
ON.
Thermoregulator display on control panel
should illuminate (see
Figure 38).
Figure 37. Resetting the switch.
8. Turn glue pot ON (see Figure 38).
Note: Glue pot filled with glue at factory.
Figure 38. Thermoregulator display illuminated
after master power switch turned
ON.
Thermoregulator
Display
Upper
Number
Glue Pot
ON/OFF Switch
Summary of Contents for G0854