Throttle channel settings:
In this menu, a throttle curve with 4 points can be established.
Curve: ON - OFF
activates or deactivates the throttle curve
0% -> 0% :
display of the current position of the throttle
lever in percent
POINT
: N - H =
Neutral - Full throttle
:
Display of the position of the 4 points on the curve
SW:
Here, the switch is shown which has been assigned to the function in the
SW FUN menu
.
The switch can be used to activate or deactivate the Dual Rate function. (Only one pressure switch
or trim button can be assigned)
If you press
ENTER
at the position at which you want to alter the curve, a point is created, and the
curve value can be changed at the respective position. A maximum of 4 points can be set.
0%
If you have highlighted the field
in the
POINT
line and then press the
INC
button,
Trim point
appears
in the 2nd line.
Here, you can use the
INC/DEC
button, to
select the point on the curve to be changed and move it
with the
UP/DOWN
button. Pressing the
INC/DEC
button
simultaneously = deletes the point. In the SW FUN menu,
the values for shifting the points can be assigned to trim
buttons, by assigning the functions TH CP2 - TH CP6 to a
trim button.
0%
If you have selected "ON" in the
CURVE
line, the throttle curve will be smoothed.
If you have selected "OFF" in the
CURVE
line, the throttle curve acts directly.
If you have highlighted the field in the
POINT
line and then
2x press the
INC
button,
Trim X-axis
appears in the 2nd
line.
If you move to a point with the throttle lever, you can
move the point up and down with
UP/DOWN
and to the left
and right with
INC/DEC
. In the
SW FUN
menu, the values
for shifting the points can be assigned to trim buttons, by
assigning the functions TH CP2 - TH CP6 to a trim button.
Summary of Contents for X-8N