38
Sirius Remote Control Panels
Taking a Salvo
3 Press the desired Source button. That source will be routed to that destination and the
Source button will illuminate.
+
Note
+ ☞
Note
Sources for locked Destinations cannot be changed.
Taking a Salvo
Up to eight salvos can be configured on a Sirius router. Each salvo can route any number of
sources to any number of destinations, including the same source to multiple destinations.
Crosspoints not included in a salvo remain unchanged. See
page 28 to learn how to configure salvos.
Performing a salvo is a two stage process. First you arm the salvo, and then you take the
salvo.
1 Press the desired Salvo button. The button will blink for five seconds.
2 Press that blinking Salvo button again to take that salvo.
After five seconds, the Salvo button will no longer be armed and will stop blinking. To take
that salvo you will need to press the Salvo button again to rearm that salvo.
+
Note
+ ☞
Note
Salvos do not change locked Destinations.
Connectors and Indicators
Fig. 4-1: Sirius Control Panel Connectors and Indicator
Power Connectors
Sirius control panel provides inputs for two power supplies—one included, redundant
supply optional.
RJ-45 LAN
Ethernet
Connection
Identify LED
PS 1 & PS 2
Power Supply
Connectors