35
Sirius Compact Routers
Installation and User Manual
• For a Sirius router, insert a straightened paper clip or similar device into the reset
slot on the rear.
• For a Sirius CP, press and hold the two SHIFT buttons on the panel.
3 Apply power to the device, wait at least 5 seconds and then release the reset function.
Fig. 3-13: Sirius Reset Locations
Sirius Alarms
Sirius reports alarms on the router front panel by lighting an Alarm LED and in the web
browser UI by illuminating the border of the Alarms tab (see below). Alarms include:
• Power Supply – displays error if a redundant power supply is off-line
• Reference – displays error if no valid video reference signal is found
• Over Temperature – displays error if Sirius exceeds normal operating temperature
Fig. 3-14: Sirius Web Interface, Alarms Screen
If you do not want any of the above conditions to report an error, click the boxed text to
access the drop-down menu shown above. Select Suppress and click OK to deactivate the
specific alarm.
Locating a Specific Sirius
Click on the Web UI Identify button to find the physical location of the currently controlled
Sirius router or panel.
Sirius Control Panel
Sirius Router
Press Both Buttons
Recessed Button
Under Slot