LCX603-UM-651-9370
2-65
2 Setup
(7) Release the ribbon lever.
Ribbon lever
(8) When the ribbon lever released, the following message will be displayed.
Confirm Combination!
H3=Semi-R H2=RESIN
H1=RESIN
YES:ENTER NO:ESC
(9) Press the FEED Key until the printed media comes out from the exit area of the LCX603.
(10) Measure the first page of X distance between crosses printed with Head 3 (ribbon 3), and enter the
correction value.
Y
X
Printed with head 3
Feeding direction
Correction value = 190.0 mm -measured value
Printed with head 2
Wrinkle
prevention
lines
Measure the length (measured value)
For example in the above illustration, the correction value becomes negative when “correction value =
190.0 mm - measured value” and the measured value was made 190.5 mm. (Correction Value: Input
as -0.5 mm)
Summary of Contents for LABELROBO LCX603