6-4
Chapter 6 TROUBLESHOOTING
6.2 Error Messages
Symptom/Error message
Cause
Solution
•
The beeper sounds.
•
The POWER lamp lights.
OVER CURRENT
POWER OFF THEN ON
POSITION ALARM
POWER OFF THEN ON
Excessive load is causing the current to the
motor to exceed the rated value.
•
The cutting conditions do not suit the
cutting medium.
Turn off the plotter, remove the obstacle, and
then turn the plotter back on.
Turn off the plotter, remove the obstacle, and
then turn the plotter back on.
•
Movement of the pen carriage is being
obstructed.
•
The pen carriage was subjected to
external pressure during cutting.
•
Scraps of the medium in the plotter's
moving parts are impeding operation.
Turn off the plotter, remove the scraps, and
then turn the plotter back on.
•
The writing panel was in a tilted position
when a key reset operation was
performed (the [ENTER] and [ORIGIN]
keys were held down simultaneously).
Move the pen carriage to its lowermost
position, and then turn the plotter off and
back on again.
•
The beeper sounds.
•
The POWER lamp lights.
SPEED ALARM
POWER OFF THEN ON
•
The POWER lamp lights.
TOOL POSITION ALARM
•
Immediately after turning on the plotter,
excessive force was used to manually
move the pen carriage.
Turn the plotter off then back on again.
•
The
•
The tool height sensor detected abnormal
height position.
internal speed control is faulty.
Turn the plotter off then back on again.
* If the error occurs frequently, contact your
sales representative or nearest Graphtec
dealer.
Turn the plotter off then back on again.
* If the error occurs frequently, contact your
sales representative or nearest Graphtec
dealer.
Summary of Contents for CUTTING PRO FC2250 Series
Page 1: ...USER S MANUAL MANUAL NO FC2250 UM 151 FC2250 SERIES CUTTING PRO www delinit by...
Page 104: ...5 29 Chapter 5 FUNCTION SETTINGS AND OPERATIONS Cutting Plotting Conditions List...
Page 120: ...CHAPTER 8 SPECIFICATIONS PRODUCT SUMMARY 8 1 Main Specifications 8 2 External Dimensions...
Page 129: ...www delinit by...