CS610-UM-251-9370
8-17
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.13 CIS (Charge Coupled Device Imaging Sensor) Assembly
Detaching the CIS assembly
(1) Detach the contact glass assembly (see Section 8.12).
(2) Slide each CIS assembly to the left side, lift it up from the right side, and then detach each CIS
assembly.
(3) Disconnect the flexible cable from each CIS assembly and then detach each CIS assembly.
Flexible cable
Flexible cable
Reattaching the CIS assembly
(1) Reattach each CIS assembly in the reverse order in which it was detached.
(2) Perform the software adjustment.
When replacing the CIS assembly, be sure to clean the interior of the image sensor unit and the inside of the
contact glass assembly. A soiled or dusty unit can affect scanning performance.