Depending on the type of floor, the appliance may need to be secured to the floor:
the appliances must be
secured with the provided dowels. If this indication is not followed, the appliance may move, causing dam-
age to persons, animals, or objects.
To secure the appliance to the floor, make holes of a suitable diameter for the provided dowels. Always
make sure that the appliance is levelled.
In the event the appliance must be moved, level and secure it again.
1. M8 screw
2. M8 safety nut
3. M8 nut
4. Machine frame
5. Washer
6. Raised frame (if provided)
7. Concrete floor
8. Anchoring bolt
9. Supplied dowels
The appliances have one hot water inlet (max 90°C) and two cold water inlets (for soft and hard water).
See paragraph 3.3
The table below allows you to determine the hardness of water according to the most common unit of
measurements .
Place wall gate valves at a distance that must not exceed the length of the provided pipes.
Classification
mmol/dm3
°dH (German de-
grees)
°fH (French de-
grees)
English degrees
Soft
0
→
1.25
0
→
7
0
→
12
0
→
8.75
Average
1.25
→
2.5
7
→
14
12
→
25
8.75
→
17.5
Hard
2.5
→
3.75
14
→
21
25
→
37
17.5
→
26.3
Very hard
>3.75
>21
>37
>26.3
Attention!
•
In the event hot water or soft cold water is not available, provide one
or two T-connections to always supply all the inlets of the appliance.
4.6.2 WATER CONNECTION
Attention!
•
Do not connect the water inlets with rigid pipes.
•
Use the supplied pipes only.
•
Rigid pipes can cause problems due to the vibrations generated by the
appliance during normal operation.
•
The water supply connections of the appliances are made of plastic.
Follow the procedure below to tighten the hose ring-nut correctly.
{
Manually tighten the nut until it locks.
{
Make a quarter turn with a fixed spanner.
•
At the end of the assembly operation, make sure that there are no
bottlenecks or crushed parts in the used pipes.