During the progress of the module, you can choose whether GUIDO® must maintain the set
temperature for the entire time of the module or whether heating no longer needs to be acti-
vated once the set temperature is reached for the first time.
The lower the value the more precise the temperature. Very low values are useful in the event
disinfection is required or if natural-based detergents are used, which require low and constant
temperatures for several minutes.
7.3.7 HYSTERESIS OR HEAT-REGULATION
Attention!
•
By setting "NO heat-regulation," electrical consumptions are reduced.
However, the water temperature will drop once the value set for the
module is reached for the first time;
•
On the other hand, setting heat-regulation increases electrical con-
sumptions of the appliances and improves washing efficiency;
•
The operator must choose according to the specific requirements;
•
All the pre-loaded programmes have heat-regulation active at a normal
value (-5 °C compared to the set-point value).
It is possible to set how the drum must move during the module and to define when the move
-
ment must start and end.
All users can choose between the predefined settings indicated here and related to the load
capacity of each appliance.
•
Light
•
Normal
•
Dynamic
•
Defined by the user:
•
Speed
•
Rh/Lh activation
•
Pause
Moreover, the expert laundry operator can define the type of activation of the drum if required.
The movement start can be:
Standard;
Upon reaching water level;
Upon reaching water temperature;
With the first option, movement must start together with the module; with the second option,
movement must start when the level is reached; with the third option, movement must start
when the temperature is reached.
The last option refers to the end of the movement, which can be:
•
No
•
When drain 1 or 2 drain
•
At the end of temp/level maintenance
•
At the end of the cooling process
The first selection involves continuous movement of the drum until the beginning of the sub
-
sequent module if any.
For the second option, the movement must coincide with the opening of drain 1 or 2. The other
two options are obvious.
7.3.8 DRUM MOVEMENT