Remove the packaging:
•
Cut the straps that secure the box and lift it upwards.
•
Once you have removed the external packaging, remove the nylon bag.
Attention!
•
The following conditions must be verified before installation and
use of the appliance:
{
The transit areas must at least withstand the static load of
the appliance and of the transport mean.
{
The floor where the appliance is to be installed must
withstand the dynamic and static load produced by the
appliance.
{
Wooden floors are not allowed for installation of the
appliance.
{
Check that the electric consumption of the appliance is
lower than that supplied by the electric company.
{
Check that the steam and water pressure available (for
appliances provided with this type of heating) are within
the accepted values.
Attention!
•
Store the packaging material in a safe place, which must not be
accessible to unauthorised persons.
Model
Dynamic load (kN)
Electric consumption Kw
(optional value)
Max. water pressure
(KPa)
Max. steam pressure
(KPa)
kg 8
1.9 ± 0.5 at 19.4 Hz
6-(9)
600
600
kg 11
2.2 ± 0.5 at 17.9 Hz
9-(16/12)
kg 14
2.7 ± 0.5 at 17.9 Hz
12-(9)
kg 18
4.0 ± 0.5 at 16.3 Hz
18-(12)
kg 24
4.6 ± 0.5 at 16.3 Hz
18
kg 28
5.0 ± 0.5 at 15.25 Hz
22
4.2 SAFETY PRECAUTIONS BEFORE USE
4.3 UNPACKING