06249A
Fig. 6
hydraulic bypass valve
in BYPASS position
A
B
12
308611
Operation
EMERGENCY SHUT OFF
To shut down the entire RoadLazer system, set
POWER ON/OFF on the Programmable Skipline
Controller to the OFF position.
Load Glass Beads
1. Set POWER ON/OFF on Programmable Skipline
Controller to OFF.
2. Set RoadLazer engine ignition key to OFF. Fig. 7.
3. Relieve air pressure.
4. Remove cover from bead tank.
5. Screen glass beads to prevent debris from
entering tank.
6. Load bead tank with glass beads.
Set Up Boom and Guns
1. Pull boom to left or right side of vehicle. Lock
boom clamps.
2. Remove gun arm from upright stowed position,
and slide to end of boom. Slowly lower gun arm,
and lock into position with clamp.
3. Open the paint gun ball valves on guns to be used.
NOTE:
Never open both ball valves on the
two-color gun at the same time. Paint color
contamination could result.
4. Fill a 5-gallon pail with water or compatible solvent,
and place paint suction hose in pail.
5. Place an empty pail under the drain valves to
catch drainage from drain valves.
Prepare System to Paint
Initial Settings
1. Ground RoadLazer ground strap to earth ground.
See Fig. 8 on page 14.
2. Turn on Programmable Skipline Controller.
NOTE:
Engine does not start with control off.
3. Set hydraulic bypass valve to BYPASS position.
Fig. 6.
4. Turn pump levers (A) clockwise 1/4 turn to OFF
position.
5. Turn bead system valve to OFF position.