22. If you suspect a clog, perform
23. Inspect fittings for leaks. If leaks occur, turn sprayer
OFF immediately. Perform
, page 14. Tighten leaky fittings. Repeat
Startup
, steps 1-22. If no leaks, continue to trigger
gun until system is thoroughly primed. Proceed to
step 26.
25. Close B side Fluid Valve on gun, and repeat step
14-23 for pump “A” with component A material.
26. Engage Piston Safety Lock. Use end of SwitchTip
to press OneSeal into tip guard, with curve
matching tip bore.
27. Insert SwitchTip in tip bore and firmly thread
assembly onto gun.
28. Open both A and B Fluid Valves.
29. Disengage Piston Safety Lock.
30. Turn both A and B Pump ON/OFF Valves to
ON.
31. Turn proportioning valve to “proportion”.
To avoid serious injury from skin injection, do not put
your hand in front of the spray tip when installing or
removing the spray tip and tip guard.
TI2410A
Disengaged
ti28017a