Integration
82
333587D
Pump Data Exchange
E-Flo iQ Advance Map 18E218
Data Exchange (Pump)
Command Value
(base 10 decimal)
Name
Units/Format
Read/
Write
Min
Value
Max Value
0
Pump Active Alarms
Bitfield
Read
0
2,147,483,647
1
Pump Active Deviations
Bitfield
Read
0
2,147,483,647
2
Pump Active Advisories
Bitfield
Read
0
2,147,483,647
3
Driver Resettable Cycles
xxxx Cycles
Read
0
2,147,483,647
4
Pump Resettable Cycles
xxxx Cycles
Read
0
2,147,483,647
5
Platen Resettable Cycles
xxxx Cycles
Read
0
2,147,483,647
6
Dispense Valve Resettable Cycles
xxxx Cycles
Read
0
2,147,483,647
7
Platen Valve Resettable Cycles
xxxx Cycles
Read
0
2,147,483,647
8
Driver Lifetime Cycles
xxxx Cycles
Read
0
2,147,483,647
9
Pump Lifetime Cycles
xxxx Cycles
Read
0
2,147,483,647
10
Platen Lifetime Cycles
xxxx Cycles
Read
0
2,147,483,647
11
Dispense Valve Lifetime Cycles
xxxx Cycles
Read
0
2,147,483,647
12
Platen Valve Lifetime Cycles
xxxx Cycles
Read
0
2,147,483,647
13
Pump Direction
Bit Number:
0: FIRST DOWN
1: UP
2: DOWN
3: TOP CHANGEOVER
4: BOT CHANGEOVER
Read
0
31
14
Average Motor Current
xx.xxx Amps
Read
0.000
25.000
15
Motor Temperature
xx deg C
Read
0
200
16
IGBT Board Temperature
xx deg C
Read
0
200
17
Bus Voltage
xxx.xx Volts
Read
0.00
350.00
18
Precharge Source
0 = Local 1 =
Remote/Fieldbus
Read
0
1
19
Flowrate Source
0 = Local 1 =
Remote/Fieldbus
Read
0
1
20
Delays Source
0 = Local 1 =
Remote/Fieldbus
Read
0
1