Warnings 

10

333587D

SPLATTER HAZARD

Hot or toxic fluid can cause serious injury if splashed in the eyes or on skin. During blow off of platen, 

splatter may occur.

• Use minimum air pressure when removing platen from drum.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 

swallowed.

• Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.

• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

BURN HAZARD

Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe 

burns:

• Do not touch hot fluid or equipment.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 

eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 

limited to:

• Protective eyewear, and hearing protection.

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

Summary of Contents for E-Flo 333587D

Page 1: ...scosity fluids For professional use only Not approved for use in explosive atmospheres or hazardous classified locations See page 5 for system component information Important Safety Instructions Read...

Page 2: ...ance 50 Pump Maintenance Screen 1 50 Pump Maintenance Screen 2 51 Diagnostics 52 Pump Diagnostics Screen 52 Heat Diagnostics Screen 52 Pressure Diagnostics Screen 53 Troubleshooting 54 View Errors 54...

Page 3: ...nse Valves Instructions Parts 333586 E Flo iQ Dispense System Installation Parts 3A6321 ADM Token In System Programming 312493 Light Tower Kit Instructions 3A1244 Graco Control Architecture Module 3A6...

Page 4: ...Platen Valve Option Size Drum Size Pump Materia l Seal Material Fieldbus Option EQC E Flo iQ System Revision S Single H Heated Y Yes A 3 in 20 L 5 Gal CS EPDM A Ether Net IP Hose Options for Tandem H...

Page 5: ...th Digit Check Mate Pump Options Ram Options Platen and Seal Options Interface Options Size Pump Material Heated Ambient Nam e Size Drum Size Style Platen Size Platen Materia l Seal Material Wiper Hea...

Page 6: ...at 213 F 400 F 101 C 204 C 05 19M405 10 5 8 in 15 9 mm 10 ft Heated 06 19M406 10 5 8 in 15 9 mm 15 ft Heated 07 19M407 10 5 8 in 15 9 mm 20 ft Heated 08 19M408 10 5 8 in 15 9 mm 25 ft Heated 11 19M411...

Page 7: ...dispense system design the material being pumped and the flow rate the dynamic pressure will not reach the rated working stall pressure of the system Pump Working Stall Pressure Max Dynamic Run Pressu...

Page 8: ...ng any cables and before servicing equipment This equipment must be grounded Connect only to grounded power source All electrical wiring must be done by a qualified electrician and comply with all loc...

Page 9: ...shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate...

Page 10: ...g Store hazardous fluid in approved containers and dispose of it according to applicable guidelines BURN HAZARD Equipment surfaces and fluid that is heated can become very hot during operation To avoi...

Page 11: ...the needs of the system Key A iQ Ram Supply Unit B iQ Dispense Valve C First Hose from Supply System D Second Hose to iQ Dispense Valve E Ram Supply System Fitting to First Hose F First Hose Fitting...

Page 12: ...se 2 E Tandem Block Fitting to Supply Hose 1 F Supply Hose 1 Fitting to Supply Hose 2 G Supply Hose 2 Fitting to Swivel H Swivel Fitting J Swivel Fitting to Valve K iQ Ram Supply Unit 2 L Tandem Hose...

Page 13: ...L Platen Lift Rod AM Pump Bleed Valve AN Wet Cup AR Air Line not supplied AS Air Line Drain Valve not supplied AT Air Filter not supplied AU Bleed Type Air Shutoff Valve required not supplied AV Level...

Page 14: ...t systems the Disconnect Switch AZ is located on the Power Junction Box AJ On heated systems the Disconnect Switch AZ is located on the Heat Control Box AX Heated systems also have a red and black Pow...

Page 15: ...xhaust Port with Muffler BD Blowoff Button BE turns air on and off to push the Platen D out of an empty drum Integrated Air Line Accessories See FIG 3 Air Line Drain Valve AS removes condensed water f...

Page 16: ...a selection Cancels the pump processes Exits a screen without saving changes CF Enter Select to update a field accept a selection or value acknowledge an event enter a screen and toggle selected item...

Page 17: ...s when the ADM is powered up Five seconds after the E Flo iQ blue token is inserted into the ADM the Graco power up screen switches to the E Flo iQ power up screen This screen remains on while the ADM...

Page 18: ...is displayed If the system is not locked password is set to 0000 iQ Menu Screen 1 is displayed Refer to iQ Menu on page 22 for additional information Press on any Setup screen to return to the Run sc...

Page 19: ...Function Alarm See Troubleshooting page 54 for more information Deviation See Troubleshooting page 54 for more information Advisory See Troubleshooting page 54 for more information Target for primary...

Page 20: ...creen Access the Advanced System Setup screens Access the Maintenance function Access the Fieldbus Gateway Setup screens Access the Integration Feedback screens Globalize selection Apply a style setti...

Page 21: ...s into setback and out of setback Enter or exit manual pump movement mode Move to the top Move upward Move downward Move to the bottom Reset Cycle Counter Toggle between lifetime and resettable Calibr...

Page 22: ...on the ADM from any Run screen to go to the iQ Menu screens iQ Menu Screen 1 iQ Menu Screen 2 If you set a password the menu will be displayed with red locks above the menu selections with parameters...

Page 23: ...that it is an E Flo iQ system The Pump shows as Installed The Serial Number should match the serial number printed on the driver ID tag As a backup to the driver serial number the serial number of the...

Page 24: ...s on page 41 NOTE Through fieldbus only a style number greater than 16 can be passed over to the E Flo iQ However style definitions and delays must come from the fieldbus Style Screen 1 Style Definiti...

Page 25: ...t key is the backspace to delete one letter at a time Press the soft key to save the name and exit the keyboard screen Press the soft key to exit the screen without saving Both actions return you to S...

Page 26: ...changes and exit editing mode Pump Settings Press the soft key at iQ Menu screen 1 to access the Pump setup screens This function allows you to configure the operating settings for the pump and drum d...

Page 27: ...hange the values and select minus or plus from the drop down menus as appropriate for the calibration 7 Press the soft key to save your changes and exit editing mode Pump Screen 2 Drum Settings Use th...

Page 28: ...ee the System Setup Screen on page 23 Heat Setup Screen 1 NOTE For Tandem systems read this section first then refer to Tandem Heat Setup Screen 1 on page 29 The heat zone number in the first column c...

Page 29: ...d all of Heat Setup Screen 1 starting on page 28 before reading this section The Heat Setup screens for Ram and Tandem are the same in appearance except Tandem has an additional column to the right fo...

Page 30: ...p and platen zones and the zone for the hose that runs from the ram supply unit for P2 to the Ball Valve S on the Tandem Block R since all others are controlled by P1 7 Press the soft key to save your...

Page 31: ...deviation and the represents high and low 3 Press the soft key to save your changes and exit this screen Heat Setup Screen 4 Use the ADM Directional Keypad CH to navigate to Heat screen 4 The Tandem...

Page 32: ...it is set to Enable or a level has the rights to change the display control 8 Press the soft key to save your changes and exit editing mode Advanced Setup Screen 2 Use the ADM directional keypad BH t...

Page 33: ...d setbacks through the Heat Run screen See Heat Run Screen on page 44 8 Press the soft key to save your changes and exit editing mode Advanced Setup Screen 4 Use the ADM Directional Keypad CH to navig...

Page 34: ...mming manual for a detailed description of this screen See Related Manuals on page 3 Connect Light Tower Assembly 1 Order the 255468 Light Tower Accessory as a diagnostic indicator for the E Flo iQ Sy...

Page 35: ...up button CA on the ADM AF to enable the system 6 At the ADM AF Run screen press the soft key next to the icon to enter editing mode 7 Press the soft key to enter the pump priming mode Two fields appe...

Page 36: ...BC up to raise the Ram AA to its full height 5 Set the Ram Director Valve BC to neutral horizontal position 6 Lubricate the Platen Wiper with grease or another lubricant compatible with the material b...

Page 37: ...with no air comes out of the Pump Bleed Valve AM close the valve 9 Press the soft key to stop the Pump AC Load the Platen Valve and Recirculation Hose NOTE The following steps only apply to systems th...

Page 38: ...m Block R 4 Press the soft key to switch to the currently operating ram supply unit The one currently operating is highlighted in green The Prime icon displays the number of the other ram for priming...

Page 39: ...Depressurization Mode on page 42 9 Select to enter or exit dispense valve depressurization mode See Depressurization Mode on page 42 10 Select to enter or exit priming mode See Priming Mode on page 42...

Page 40: ...or exit drum depressurization mode See Depressurization Mode on page 42 10 Select to enter or exit dispense valve depressurization mode See Depressurization Mode on page 42 11 Select to enter or exit...

Page 41: ...pense manually This icon is only available when the ADM is in Local control mode See Control Modes on this page This icon changes based on the status of the pump NOTE Customer Go Signal can be used in...

Page 42: ...On a Tandem system open the Ball Valves S on the Tandem Block R 1 Press the soft key to enter the pump priming mode 2 To control the flow of material set your target pressure and target flow in the fi...

Page 43: ...ove the low level sensor is set to Deviation and the empty level sensor is set to Alarm to stop operation of the pump Run Screen Editing Mode Press the soft key to enter editing mode Press the soft ke...

Page 44: ...tem is placed in setback the temperature displayed in the box is the setback value The temperature units can be changed from C to F in the Advanced Settings screens See Advanced Setup Screen 2 on page...

Page 45: ...perature in the zone setpoint setback temperature box 3 Press the soft key to take the system out of setback If all of the existing heat zones are disabled the readings on the Heat Run screen will be...

Page 46: ...the time of the valve opening The Job Log maintains a record of the last 204 jobs that were performed Use the ADM directional keypad BH to scroll through the pages Red text on the Job Log screen indic...

Page 47: ...nts listed on this screen can be downloaded on a USB flash drive To download logs see the Download Procedure on page 65 Errors Log Screen This screen shows the Date Time Error Code and Description of...

Page 48: ...tion Then press the soft key to open the Dispense Valve A allowing the system to depressurize 3 The current pump pressure and current dispense valve pressure show the progress of the depressurization...

Page 49: ...e Ram AA cylinders Shutdown the System 1 Follow the Pressure Relief Procedure on page 48 NOTE If using a Tandem system perform these steps on both units 2 Set the Ram Director Valve BC to DOWN and low...

Page 50: ...ve to each one you want to reset and press the soft key NOTE Reset the counter after maintenance is completed 4 Press the soft key to exit editing mode Press the soft key to enter manual pump movement...

Page 51: ...pump cycles at maximum force would be all the way to the right at 100 Five pump cycles at minimum force would be all the way to the left at 0 Press the soft key to toggle between the histogram display...

Page 52: ...rate an alarm and shut down the pump The Bus Voltage is the DC voltage of the driver bus The Motor Curren is the active current that is being used by the driver The pump position is shown in inches Th...

Page 53: ...n on the right shows the remaining time that the zone will be in heat soak The Line Voltage at the far right of the screen shows the current system voltages coming into the AMZ Pressure Diagnostics Sc...

Page 54: ...the soft key to advance to the QR Code screen for the selected error See Troubleshoot Errors on this page Press the soft key to advance to a keyboard screen that allows you to search for an error by e...

Page 55: ...ons are indicated by This condition indicates a parameter critical to the process has reached a level requiring attention but not sufficient enough to stop the system at this time Advisories are indic...

Page 56: ...wires are touching and that no wires are shorted to ground Motor not able to rotate Check that motor shaft rotates freely Flow rate is too large for the motor to drive the pumps at the operating press...

Page 57: ...n the ADM and driver Yellow LED on driver connector board should be flashing CBD_ Driver Alarm Communication Error P_ Communicatio n lost between pump and ADM No AC power to driver Verify pump is turn...

Page 58: ...io n lost between driver hot and cold boards Software update failure If software updates to the hot or cold driver boards fail before completion then they will not be able to communicate Update softwa...

Page 59: ...Advisory Download to USB In Process Information is currently being downloaded to USB Download to USB initiated No action necessary Self clearing EAW_ AMZ Record Only Heat_ Module Warming Up All zones...

Page 60: ...USB drive F1D_ F2D_ Pump Alarm or Deviation user selectable Low Flow Rate P_ Measured flow rate less than desired flow rate minus tolerance Fluid supply too low to achieve desired flow rate Increase f...

Page 61: ...number of platen valve cycles since last reset has exceeded the maintenance limit set Perform desired maintenance and reset the platen valve cycles in the setup screen MED_ Pump Advisory Maint Due Di...

Page 62: ...eat zone is offline The AMZ lost communication with the other Tandem AMZ Restore communication T1__ AMZ Alarm Low Temperature H_Z_ Temperature of the zone is below the setpoint Zone has reached setpoi...

Page 63: ...n element See manual to find correct location of RTD on element T6__ AMZ Alarm Sensor Error H_Z_ The zone has no reading from RTD No reading from the RTD of the heat zone Check the wired connections t...

Page 64: ...ned off Disconnected switches Turn on the disconnected switches WMG0 Gateway Alarm Gateway Error Detected Gateway error detected includes any error not covered by a more specific error WMN_ Driver Ala...

Page 65: ...TAxxxx folder 10 Open the DATAxxxx folder labeled with the highest number The highest number indicates the most recent data download 11 Open the log file Log files open in Microsoft Excel by default a...

Page 66: ...s that are used by Graco to further diagnose the status of the system System Configuration Settings The system configuration settings file name is SETTINGS TXT and is stored in the DOWNLOAD folder A s...

Page 67: ...ove rows to the file Do not change the order of the rows Upload Procedure Use this procedure to install a system configuration file and or a custom language file 1 If necessary follow the Download Pro...

Page 68: ...is ON 1 V is OFF Style Enable When the digital input is ON the pump will start a job and begin pre charge if active When the digital input is OFF the pump will not be running a job Graco Customer 3 Gr...

Page 69: ...to the E Flo iQ Supply System Installation Parts Manual for additional information about Electric Driver Connections See Related Manuals on page 3 FIG 9 Electric Driver Connections Connector 3 Connec...

Page 70: ...Pre charge will only be active when there is a set point stored in the display or passed over the CGM The dispense complete is optional This bit summates the volume dispensed any time it is triggered...

Page 71: ...e Remote Start Request C4 5 6W OH QDEOH Prechargring R 6LJQDO DV UHTXLUHG Dispense Complete C4 1 Notes DQ EH HQDEOHG DW WKH VDPH WLPH LI WKHUH LV QR SUHFKDUJH The dispense complete is optional This bi...

Page 72: ...Map table NOTE If the PLC connection parameters are not setup correctly the connection between the E Flo iQ and PLC will not be made Available Internal Data Unless stated otherwise bytes are stored in...

Page 73: ...are Present Boolean 0 1 5 A 7 No Advisories are Present Boolean 0 1 6 A 8 System Ready to dispense Boolean 0 1 7 A 9 Pre charge De charge Active Boolean 0 1 0 1 A 10 Dispense In Process Boolean 0 1 1...

Page 74: ...6 0 14 26 27 A 43 Actual Style Fieldbus Flowrate Request xxxx cc min uint16 0 6000 0 14 28 29 A 44 Reserved Word 3 uint16 0 14 30 31 A 45 Pump Position x xxxx inches uint16 0 0000 4 0000 0 14 32 33 A...

Page 75: ...pressurization Active Boolean 0 1 1 A 74 Auto Depressurization Happened Boolean 0 1 2 A 75 Pump is trying to move Boolean 0 1 3 A 76 Pump is actually moving Boolean 0 1 4 A 77 Dispense Valve Opened Bo...

Page 76: ...Alarms are Present Boolean 0 1 4 H 105 No Heat Zone s Deviations are Present Boolean 0 1 5 H 106 No Heat Zone s Advisories are Present Boolean 0 1 6 H 107 Heat Idle Timeout Happened Boolean 0 1 7 H 1...

Page 77: ...3 H 139 No Heat Zone s Alarms are Present Boolean 0 1 4 H 140 No Heat Zone s Deviations are Present Boolean 0 1 5 H 141 No Heat Zone s Advisories are Present Boolean 0 1 6 H 142 Heat Idle Timeout Happ...

Page 78: ...67 0 14 88 89 H 161 Heat Data Exchange Element Value Feedback uint32 See heat data exchange for min and max values 0 31 90 93 H E Flo iQ Maps 18E218 and 18E224 Automation INPUTS signal from E Flo iQ t...

Page 79: ...le Enable Request Boolean 0 1 3 A 6 Go Signal Request use discrete signal for proper timing Boolean 0 1 4 A 7 Dispense Complete Request Boolean 0 1 5 A 8 Tandem Crossover Request Boolean 0 1 6 A 9 Pri...

Page 80: ...Disable Request Boolean 0 1 1 H 30 Heat PLC Lockout Control Request Boolean 0 1 2 H 31 Heat On Request Boolean 0 1 3 H 32 Heat Off Request Boolean 0 1 4 H 33 Heat Setback Request Boolean 0 1 5 H 34 A...

Page 81: ...H 54 Reserved Bit 2 Boolean 0 33 H 55 Reserved Bit 3 Boolean 1 H 56 Reserved Bit 4 Boolean 2 H 57 Reserved Bit 5 Boolean 3 H 58 Reserved Bit 6 Boolean 4 H 59 Reserved Bit 7 Boolean 5 H 60 Reserved Bit...

Page 82: ...able Cycles xxxx Cycles Read 0 2 147 483 647 8 Driver Lifetime Cycles xxxx Cycles Read 0 2 147 483 647 9 Pump Lifetime Cycles xxxx Cycles Read 0 2 147 483 647 10 Platen Lifetime Cycles xxxx Cycles Rea...

Page 83: ...Voltage Leg 2 xxx x Volts Read 0 0 400 0 A Line Voltage Leg 3 xxx x Volts Read 0 0 400 0 Transition to Zones z000 AMZ Active Zone z Alarms Bitfield Read 0 2 147 483 647 z001 AMZ Active Zone z Deviatio...

Page 84: ...erature Alarm Offset xx x deg C Read Write 0 30 0 z00F Zone z High Temperature Deviation Offset xx x deg C Read Write 0 30 0 z010 Zone z Low Temperature Alarm Offset xx x deg C Read Write 0 30 0 z011...

Page 85: ...Display Comm Error P_ 21 P6V_ Valve Pressure Sensor P_ 22 WSN_ Invalided Style P_ 23 WNC_ iQ Software Not Selected P_ 24 WMH_ Control Board Off P_ 25 Reserved 26 Reserved 27 Reserved 28 Reserved 29 Re...

Page 86: ...re P_ 4 MG3_ High Filter Pressure P_ 5 MLD_ Maint Due Platen Valve P_ 6 MED_ Maint Due Dispense Valve P_ 7 Reserved 8 Reserved 9 Reserved 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15...

Page 87: ...d 22 Reserved 23 Reserved 24 Reserved 25 Reserved 26 Reserved 27 Reserved 28 Reserved 29 Reserved 30 Reserved 31 Reserved AMZ Active Module Deviation Bitfield Bit Number Deviation Code Deviation Name...

Page 88: ...O Daughter Board Active Module Alarms Bitfield Bit Number Alarm Code Alarm Name 0 TA1_ Heat Zone Offline Z1 H_ 1 TA2_ Heat Zone Offline Z2 H_ 2 TA3_ Heat Zone Offline Z3 H_ 3 TA4_ Heat Zone Offline Z...

Page 89: ...rved 23 Reserved 24 Reserved 25 Reserved 26 Reserved 27 Reserved 28 Reserved 29 Reserved 30 Reserved 31 Reserved I O Daughter Board Active Module Advisories Bitfield Bit Number Advisory Code Advisory...

Page 90: ...eserved 17 Reserved 18 Reserved 19 Reserved 20 Reserved 21 Reserved 22 Reserved 23 Reserved 24 Reserved 25 Reserved 26 Reserved 27 Reserved 28 Reserved 29 Reserved 30 Reserved 31 Reserved AMZ Active Z...

Page 91: ...H_Z_ 3 Reserved 4 A3__ High Current H_Z_ 5 A2__ Low Current H_Z_ 6 Reserved 7 Reserved 8 Reserved 9 Reserved 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15 Reserved 16 Reserved 17 Rese...

Page 92: ...Active 15 70 Automation Outputs E Flo iQ Inputs Pump PLC Lockout Control Request Prime Pressure Target integer Prime Flow Target integer Prime Pump Request integer Tag ID Notes When in Tandem mode se...

Page 93: ...OYH HSUHVVXUL DWLRQ 5HTXHVW 10 Automation Inputs E Flo iQ Outputs Tag ID Active Pump Pump Heartbeat To PLC 1 Automation Control Ready 2 Pump PLC Lockout Control Active 4 Platen Depressurization Active...

Page 94: ...1 56 System Active 3 58 No Alarms are Present 5 60 Automation Control Ready 2 57 Automation Outputs E Flo iQ Inputs System Enable Remote Start Request Tag ID 2 The system must be in remote mode and th...

Page 95: ...ield No Advisories are Present 7 62 Automation Outputs E Flo iQ Inputs Acknowledge Clear Errors Request Notes Each pump has to be checked for errors If there is an error the corresponding error bitfie...

Page 96: ...dem Crossover Request 8 Pump 1 Active Pump 2 Active Data Exchange Automation Inputs E Flo iQ Outputs Active Pump Inactive Pump Pump Heartbeat To PLC 1 56 Pump Data Exchange Element Feedback integer 54...

Page 97: ...92 127 Sy stem Heat Enabled 93 128 Heat PLC Lockout Control Activ e 94 129 Automation Outputs E Flo iQ Inputs Sy stem Heat Enabled Request 28 46 Sy stem Heat Disable Request 29 47 Heat PLC Lockout Con...

Page 98: ...omation Outputs E Flo iQ Inputs FNQRZOHGJH OHDU HDW UURUV 5HTXHVW 34 52 Automation Inputs E Flo iQ Outputs H1 H2 Heat Heartbeat To PLC 92 127 OR L4 HDW DWD FKDQJH 0 FWLYH 0RGXOH GYLVRULHV LQWHJHU ELWI...

Page 99: ...Inputs E Flo iQ Outputs H1 H2 Heat Heartbeat To PLC 92 127 OR L4 HDW DWD FKDQJH 0 FWLYH RQH GYLVRULHV LQWHJHU ELWILHOG 1R HDW RQH V GYLVRULHV DUH 3UHVHQW 106 141 Automation Outputs E Flo iQ Inputs FN...

Page 100: ...ack integer 125 160 Heat Data Exchange Element Value Feedback integer 126 161 Automation Outputs E Flo iQ Inputs Heat PLC Lockout Control Request 30 48 Heat Data Exchange Element Command integer 44 62...

Page 101: ...tate TI11814A NS MS Link State Description Comments Off Not initialized No power or module in SETUP or NW_INIT state Green Normal operation Diagnostic event s present Flashing Green Initialized diagno...

Page 102: ...Idle state Red Major fault EXCEPTION state FATAL error etc Flashing Red Recoverable fault s State Description Off No link no activity Green Link established Flashing Green Activity TI11814A NS MS Link...

Page 103: ...ion Off No power or not initialized Green Initialized Flashing Green Initialized diagnostic event s present Red Exception error Pin Signal Description 1 2 3 B Line Positive RxD TxD RS485 level 4 RTS R...

Page 104: ...Some screens are informational only For those that can be edited press the soft key to enter editing mode Use the Directional Keypad CH and Numeric Keypad CJ to make changes PROFINET PROFINET Screen...

Page 105: ...You can view the Hardware Revision System Serial number and data map identification information at this screen PROFIBUS PROFIBUS Screen 1 This screen allows you to set the Device Address Install Date...

Page 106: ...Integration 106 333587D DeviceNet At this screen you can set the Device Address and Baud Rate and view the Hardware Revision System Serial number and data map identification information...

Page 107: ...E Flo iQ The numbers to the right of each signal represent the connector and pin number on the E Flo iQ driver See Connector Identification on page 69 The colors to the left of the connector pin numbe...

Page 108: ...PTFE coated aluminum 6061 aluminum Buna Viton Zinc plated steel 316 stainless steel 17 4 stainless steel 25R099 5 gal 20 L Electroless nickel plated ductile iron EPDM PTFE coated aluminum 6061 alumin...

Page 109: ...of a product s useful life recycle it in a responsible manner For additional information refer to the E Flo iQ Dispense System Installation Parts manual See Related Manuals on page 3 California Propos...

Page 110: ...made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT...