Integration
102
333587D
EtherNet/IP
The EtherNet interface operates at 100Mbit, full duplex,
as required by PROFINET. The EtherNet interface is
auto-polarity sensing and auto-crossover capable.
Network Status (NS)
Module Status (MS)
LINK/Activity (Link)
DeviceNet
Network Status (NS)
Module Status (MS)
DeviceNet Connector (DC)
State
Description
Off
No power or no IP address
Green
On-line, one or more connections established
(CIP Class 1 or 3)
Flashing
Green
On-line, no connections established
Red
Duplicate IP address, FATAL error
Flashing
Red
One or more connections timed out (CIP Class
1 or 3)
State
Description
Off
No power
Green
Controlled by a Scanner in Run state
Flashing
Green
Not configured, or Scanner in Idle state
Red
Major fault (EXCEPTION-state, FATAL error
etc.)
Flashing
Red
Recoverable fault(s)
State
Description
Off
No link, no activity
Green
Link established
Flashing
Green
Activity
TI11814A
NS
MS
Link
State
Description
Off
Not online / No power
Green
On-line, one or more connections are
established
Flashing
Green
(1 Hz)
On-line, no connections established
Red
Critical link failure
Flashing
Red (1 Hz)
One or more connections timed-out
Alternating
Red/Green
Self test
State
Description
Off
No power or not initialized
Green
Initialized
Flashing
Green (1 Hz)
Missing or incomplete configuration,
device needs commissioning
Red
Unrecoverable Fault(s)
Flashing
Red (1 Hz)
Recoverable Fault(s)
Alternating
Red/Green
Self test
Pin
Signal
Description
1
V-
Negative bus supply voltage
2
CAN_L
CAN low bus line
3
SHIELD
Cable shield
4
CAN_H
CAN high bus line
5
V+
Positive bus supply voltage
TI11815A
NS
MS
DC
2 3 4 5
1