Troubleshooting
60
333587D
EDT_
AMZ
Record
Only
Heat_ Module is
at desired
temperature
All zone on
heat module
are at desired
temperature
All zones on heat
module have
successfully
reached the
desired
temperature
No action necessary if the desired
temperature was reached.
EKA
Pump
Record
Only
Automatic
Crossover to P_
The system has
success
crossover to
the other the
other pump
The alarm in the
system requested a
crossover to the
other pump
No action necessary.
EKM
Pump
Record
Only
Manual
Crossover to P_
The system has
received a
crossover
request
The system has
received a
crossover request
from the ADM or
CGM
No action necessary.
EL0X
ADM
Record
Only
Power On
The ADM was
powered on
The ADM was
powered on
No action necessary.
EM0X
ADM
Record
Only
Power Off
The ADM was
powered off
The ADM was
powered off
No action necessary.
EVUX
ADM
Advisory
USB Disabled
USB
downloads/upl
oads are
disabled
USB
download/upload
was attempted, but
USB activity is
disabled within the
setup screen
Advisory will clear when drive is removed.
Enable USB downloads/uploads in setup
screen if desired and reinsert USB drive.
F1D_
F2D_
Pump
Alarm or
Deviation
(user
selectable)
Low Flow Rate
P_
Measured flow
rate less than
desired flow
rate minus
tolerance
Fluid supply too
low to achieve
desired flow rate
Increase fluid pressure to reach desired
rate.
Clog in fluid supply
system
Check hose and other components in fluid
supply system for clogs.
No air pressure to
solenoid valves
Turn on air to solenoid valves.
No material supply
Replace drum and prime pump if desired.
Incorrect flow
tolerance
Enter correct flow tolerance percentage in
setup screen.
F3D_
F4D_
Pump
Alarm or
Deviation
(user
selectable)
High Flow Rate
P_
Measured flow
rate greater
than desired
flow rate plus
tolerance
Incorrect flow
tolerance
Enter correct flow tolerance percentage in
setup screen.
L1C_
Pump
Alarm
Drum Empty P_
Drum is empty
Drum is empty and
needs to be
replaced
Replace drum and prime pump if desired.
Drum level sensor
is disconnected
Verify level sensor is connected. Replace
sensor if connection is good.
L2C_
Pump
Deviation
Drum Empty P_
Drum level is
low
Fluid level in drum
is low. Consider
replacing soon
Clear deviation and return to normal pump
operation.
Drum level sensor
is disconnected
Verify level sensor is connected. Replace
sensor if connection is good.
Error Location Type
Error Name
Error
Description Cause
Solution