Integration
333587D
103
PROFIBUS
Operation Mode (OP)
Status Mode (ST)
PROFIBUS Connector (DC)
State
Description
Off
Not online / No power
Green
On-line, data exchange
Flashing
Green
On-line, clear
Flashing Red
(1 flash)
Parameterization error
Flashing Red
(2 flashes)
PROFIBUS Configuration error
State
Description
Off
No power or not initialized
Green
Initialized
Flashing
Green
Initialized, diagnostic event(s) present
Red
Exception error
Pin
Signal
Description
1
-
-
2
-
-
3
B Line
Positive RxD/TxD, RS485 level
4
RTS
Request to send
5
GND Bus
Ground (isolated)
6
+5V Bus
Output
+5V termination power (isolated)
7
-
-
8
A Line
Negative RxD/TxD, RS485 level
9
-
-
Housing
Cable
Shield
Internally connected to the
Anybus protective earth via cable
shield filters according to the
PROFIBUS standard.
TI11816A
ST
OP
DC
1
2
3
4
5
9 8 7 6