Troubleshooting
333587D
63
T3__
AMZ
Advisory
High
Temperature
H_Z_
The zone
temperature
has exceeded
the setpoint
Element continues
to raise above the
setpoint
Defective RTD. Replace.
RTD not in correct
location on element
See manual to find correct location of RTD
on element.
Temperature
reading has risen
too high.
Adjust the temp offset errors in the Heat
Setup screen.
T4J_
Driver
Alarm
High Controls
Temperature P_
Temperature of
the control
board is too hot
The control board
temperature inside
the driver is too
high
Ensure ambient temperature is below 120F
(48C).
Enclosure fan not
operating
Verify fan in electrical enclosure is spinning.
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
T4M_
Driver
Alarm
High Motor
Temperature P_
Temperature of
the motor is too
hot
The motor
temperature inside
the driver is too
high
Ensure ambient temperature is below 120F
(48C).
Enclosure fan not
operating
Verify fan in electrical enclosure is spinning.
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
T4__
AMZ
Alarm
High
Temperature
H_Z_
The zone
temperature
has exceeded
the setpoint
Element continues
to raise above the
setpoint
Defective RTD. Replace.
RTD not in correct
location on element
See manual to find correct location of RTD
on element.
T6__
AMZ
Alarm
Sensor Error
H_Z_
The zone has
no reading from
RTD
No reading from
the RTD of the heat
zone
Check the wired connections to make sure
that RTD is wired correctly.
Defective RTD. Replace.
T8__
AMZ
Alarm
No Temperature
Rise H_Z_
The zone
temperature
does not
changed
The zone
temperature does
not changed
Check fuse on the AMZ that the error
element is connected to.
Check that electrical connector on the
heated hose is plugged into the AMZ.
Defective heater rods in element. Replace.
V1M_
Driver
Alarm
Low Voltage P_
Supplied bus
voltage is
below
minimum
acceptable limit
Transformer faulty
Check output voltage of transformer to
verify it is within acceptable input limits.
Incorrect line
voltage
Check line voltage to verify it is as expected
(230V, 380V, etc.).
V2H_
AMZ
Deviation
Low Voltage H_
The incoming
power is below
minimum
acceptable limit
Incoming line to
line voltage has
dropped below
175V
Verify incoming power is correct gauge for
current draw and verify incoming power
lines are securely attached to disconnect.
V4M_
Driver
Alarm
High Voltage P_
Supplied bus
voltage is
above
maximum
acceptable limit
Transformer faulty
Check output voltage of transformer to
verify it is within acceptable input limits.
Incorrect line
voltage
Check line voltage to verify it is as expected
(230V, 380V, etc.).
Error Location Type
Error Name
Error
Description Cause
Solution